Schneider Electric

Schneider Electric LC1D115004P7 IEC contactor, TeSys Deca, nonreversing, 200A resistive, 4 pole, 4 NO, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D115004P7
MPN:
LC1D115004P7
Condition:
New
Poles Description:
4P
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
TeSys Deca
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In Va:
2-18 VA 60 Hz cos phi 0.3 (at 20°C) || 2-18 VA 50 Hz cos phi 0.3 (at 20°C)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Power Dissipation Per Pole:
24 W AC-1
Control Circuit Type:
AC 50/60 Hz
Operating Time:
6...20 ms opening || 20...50 ms closing
Protective Treatment:
THIEC 60068-2-30
Pollution Degree:
3
Operating Altitude:
0...9842.52 ft (0...3000 m)
Protective Cover:
with
Product Or Component Type:
contactor
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Irms Rated Making Capacity:
1260 A at 440 V for power circuit conforming to IEC 60947
Range:
TeSys
Mechanical Durability:
8 Mcycles
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 460 V DC
Eu Rohs Directive:
Compliant with Exemptions
Height:
158 mm
Environmental Disclosure:
ENVPEP060301EN
[Icw] Rated Short-Time Withstand Current:
250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit
Inrush Power In Va:
280-350 VA 60 Hz cos phi 0.8 (at 20°C) || 280-350 VA 50 Hz cos phi 0.8 (at 20°C)
Rohs Exemption Information:
Yes
Contactor Application:
resistive load
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
Compatibility Code:
LC1D
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Electrical Durability:
0.8 Mcycles 200 A AC-1 <= 440 V
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Flame Retardance:
V1 conforming to UL 94
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
Pole Contact Composition:
4 NO
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Weight:
2.86 kg
Warranty:
18 months
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Country of Origin:
Czechia
Fire Resistance:
850°C IEC 60695-2-1
Overvoltage Category:
III
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Depth:
132 mm
Rated Breaking Capacity:
1100 A at 440 V for power circuit conforming to IEC 60947
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
$673.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 200A resistive load rating. Contactor is supplied with a 230 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 5.91 inches wide and 5.20 inches deep. It weighs 6.31 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose