Schneider Electric LC1D115ED IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VDC coil, open style
Schneider Electric
$479.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 48 VDC coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Compatibility Code:
- LC1D
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
- Contactor Application:
- motor control || resistive load
- Eu Rohs Directive:
- Compliant with Exemptions
- Minimum Switching Current:
- 5 mA for Signaling circuit
- [Uc] Control Circuit Voltage:
- 48 V DC
- Protective Treatment:
- THIEC 60068-2-30
- Pvc Free:
- Yes
- Utilisation Category:
- AC-4 || AC-3 || AC-1 || AC-3e
- Depth:
- 136 mm
- Net Weight:
- 2.5 kg
- Mechanical Durability:
- 8 Mcycles
- [Ie] Rated Operational Current:
- 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Maximum Horse Power Rating:
- 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Product Certifications:
- UL || CSA || CCC || UKCA || CE || EAC || Marine
- Irms Rated Making Capacity:
- 1260 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Inrush Power In W:
- 270-365 W 20°C)
- Maximum Operating Rate:
- 1200 cyc/h 60°C
- Mounting Support:
- rail || plate
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Associated Fuse Rating:
- 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
- Hold-In Power Consumption In W:
- 2.4-5.1 W 20°C
- Product Or Component Type:
- contactor
- Mercury Free:
- Yes
- Pole Contact Composition:
- 3 NO
- Coil Technology:
- with integral suppression device
- Time Constant:
- 25 ms
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Signaling Circuit Frequency:
- 25...400 Hz
- Pollution Degree:
- 3
- Sustainable Packaging:
- Yes
- Range:
- TeSys
- Control Circuit Voltage Limits:
- 0.75...1.2 Uc -40-55°C operational DC || 0.15...0.4 Uc -40-70°C drop-out DC || 1...1.2 Uc 55-70°C operational DC
- Rated Breaking Capacity:
- 1100 A at 440 V for power circuit conforming to IEC 60947
- Flame Retardance:
- V1 conforming to UL 94
- Sustainable Offer Status:
- Green Premium product
- Protective Cover:
- with
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Warranty:
- 18 months
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Control Circuit Type:
- DC standard
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947