Schneider Electric

Schneider Electric LC1D115FD IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D115FD
MPN:
LC1D115FD
Condition:
New
Flame Retardance:
V1 conforming to UL 94
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Height:
158 mm
Country of Origin:
Czechia
Fire Resistance:
850°C IEC 60695-2-1
Poles Description:
3P
Utilisation Category:
AC-4 || AC-3 || AC-1 || AC-3e
Maximum Horse Power Rating:
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Product Certifications:
UL || CSA || CCC || UKCA || CE || EAC || Marine
Compatibility Code:
LC1D
Maximum Operating Rate:
1200 cyc/h 60°C
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Associated Fuse Rating:
250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
Hold-In Power Consumption In W:
2.4-5.1 W 20°C
Device Short Name:
LC1D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Operating Time:
20...35 ms closing || 40...75 ms opening
Coil Technology:
with integral suppression device
Minimum Switching Current:
5 mA for Signaling circuit
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Time Constant:
25 ms
Insulation Resistance:
> 10 MOhm for Signaling circuit
Sustainable Packaging:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Environmental Disclosure:
ENVPEP060301EN
Contactor Application:
motor control || resistive load
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Control Circuit Voltage Limits:
0.75...1.2 Uc -40-55°C operational DC || 0.15...0.4 Uc -40-70°C drop-out DC || 1...1.2 Uc 55-70°C operational DC
Warranty:
18 months
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Range Of Product:
TeSys Deca
[Uc] Control Circuit Voltage:
110 V DC
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Mercury Free:
Yes
Circularity Profile:
ENVEOLI100405EN
Overvoltage Category:
III
Inrush Power In W:
270-365 W 20°C)
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Irms Rated Making Capacity:
1260 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Power Dissipation Per Pole:
24 W AC-1 || 7.9 W AC-3 || 7.9 W AC-3e
Product Or Component Type:
contactor
$479.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VDC coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose