Schneider Electric

Schneider Electric LC1D115FE7 IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 115VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D115FE7
MPN:
LC1D115FE7
Condition:
New
Contactor Application:
resistive load || motor control
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Fire Resistance:
850°C IEC 60695-2-1
Pollution Degree:
3
Heat Dissipation:
3-8 W at 50/60 Hz
Depth:
136 mm
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Ip Degree Of Protection:
IP20 front face IEC 60529
Protective Treatment:
THIEC 60068-2-30
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Product Certifications:
UL || CSA || CCC || UKCA || CE || EAC || Marine
Minimum Switching Voltage:
17 V for Signaling circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Insulation Resistance:
> 10 MOhm for Signaling circuit
Pvc Free:
Yes
Mercury Free:
Yes
Range:
TeSys
Warranty:
18 months
[Uc] Control Circuit Voltage:
115 V AC 50/60 Hz
Operating Altitude:
0...9842.52 ft (0...3000 m)
Control Circuit Type:
AC 50/60 Hz standard
Width:
120 mm
Pole Contact Composition:
3 NO
Inrush Power In Va:
280-350 VA 60 Hz cos phi 0.8 (at 20°C) || 280-350 VA 50 Hz cos phi 0.8 (at 20°C)
Minimum Switching Current:
5 mA for Signaling circuit
Device Short Name:
LC1D
Eu Rohs Directive:
Compliant with Exemptions
Maximum Operating Rate:
2400 cyc/h 60°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Compatibility Code:
LC1D
Overvoltage Category:
III
Power Dissipation Per Pole:
24 W AC-1 || 7.9 W AC-3 || 7.9 W AC-3e
Associated Fuse Rating:
250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
Circularity Profile:
ENVEOLI100405EN
Weight:
2.5 kg
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Maximum Horse Power Rating:
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Product Or Component Type:
contactor
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Poles Description:
3P
Environmental Disclosure:
ENVPEP060301EN
Range Of Product:
TeSys Deca
Net Weight:
2.5 kg
Auxiliary Contact Composition:
1 NO + 1 NC
Motor Power Kw:
30 kW at 220...230 V AC 50/60 Hz (AC-3) || 55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415...440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 65 kW at 1000 V AC 50/60 Hz (AC-3) || 18.
$479.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose