Schneider Electric LC1D115G6 IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 120VAC 60Hz coil, open style
Schneider Electric
$479.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 120 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Ith] Conventional Free Air Thermal Current:
- 200 A (at 60°C) for power circuit
- Pvc Free:
- Yes
- Mechanical Durability:
- 8 Mcycles
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Contactor Application:
- motor control || resistive load
- Inrush Power In Va:
- 300-300 VA 60 Hz cos phi 0.8 (at 20°C)
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- [Icw] Rated Short-Time Withstand Current:
- 250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- Signaling Circuit Frequency:
- 25...400 Hz
- Pole Contact Composition:
- 3 NO
- Electrical Durability:
- 0.8 Mcycles 200 A AC-1 <= 440 V || 0.95 Mcycles 115 A AC-3 <= 440 V || 0.95 Mcycles 115 A AC-3e <= 440 V
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Mercury Free:
- Yes
- Net Weight:
- 2.5 kg
- Fire Resistance:
- 850°C IEC 60695-2-1
- Coil Technology:
- without built-in suppressor module
- Compatibility Code:
- LC1D
- Overvoltage Category:
- III
- Hold-In Power Consumption In Va:
- 22-22 VA 60 Hz cos phi 0.3 (at 20°C)
- Utilisation Category:
- AC-3 || AC-4 || AC-1 || AC-3e
- Sustainable Offer Status:
- Green Premium product
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Operating Time:
- 6...20 ms opening || 20...50 ms closing
- Protective Treatment:
- THIEC 60068-2-30
- Device Short Name:
- LC1D
- Maximum Horse Power Rating:
- 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Environmental Disclosure:
- ENVPEP060301EN
- Rohs Exemption Information:
- Yes
- Motor Power Kw:
- 30 kW at 220...230 V AC 50/60 Hz (AC-3) || 55 kW at 380...400 V AC 50/60 Hz (AC-3) || 59 kW at 415...440 V AC 50/60 Hz (AC-3) || 75 kW at 500 V AC 50/60 Hz (AC-3) || 80 kW at 660...690 V AC 50/60 Hz (AC-3) || 65 kW at 1000 V AC 50/60 Hz (AC-3) || 18.
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
- Pollution Degree:
- 3
- Rated Breaking Capacity:
- 1100 A at 440 V for power circuit conforming to IEC 60947
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Eu Rohs Directive:
- Compliant with Exemptions
- Associated Fuse Rating:
- 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Flame Retardance:
- V1 conforming to UL 94
- Circularity Profile:
- ENVEOLI100405EN
- Range Of Product:
- TeSys Deca
- Sustainable Packaging:
- Yes
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Weight:
- 2.5 kg
- Protective Cover:
- with
- Irms Rated Making Capacity:
- 1260 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Poles Description:
- 3P