Schneider Electric LC1D115GD IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 125VDC coil, open style
Schneider Electric
$479.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 125 VDC coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- Utilisation Category:
- AC-3 || AC-1 || AC-4 || AC-3e
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Average Impedance:
- 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Height:
- 158 mm
- Compatibility Code:
- LC1D
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Range:
- TeSys
- Coil Technology:
- with integral suppression device
- Sustainable Offer Status:
- Green Premium product
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Maximum Operating Rate:
- 1200 cyc/h 60°C
- Overvoltage Category:
- III
- Weight:
- 2.5 kg
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Mercury Free:
- Yes
- Product Or Component Type:
- contactor
- Operating Time:
- 20...35 ms closing || 40...75 ms opening
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Maximum Horse Power Rating:
- 30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
- [Icw] Rated Short-Time Withstand Current:
- 250 A 40°C - 10 min for power circuit || 550 A 40°C - 1 min for power circuit || 950 A 40°C - 10 s for power circuit || 1100 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms
- [Ie] Rated Operational Current:
- 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Pole Contact Composition:
- 3 NO
- Tightening Torque:
- control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
- Safety Reliability Level:
- B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Associated Fuse Rating:
- 250 A gG at <= 690 V coordination type 1 for power circuit || 200 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Connections - Terminals:
- control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
- Depth:
- 136 mm
- Control Circuit Voltage Limits:
- 0.75...1.2 Uc -40-55°C operational DC || 0.15...0.4 Uc -40-70°C drop-out DC || 1...1.2 Uc 55-70°C operational DC
- [Ith] Conventional Free Air Thermal Current:
- 200 A (at 60°C) for power circuit
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Protective Cover:
- with
- Net Weight:
- 2.5 kg
- Width:
- 120 mm
- Protective Treatment:
- THIEC 60068-2-30
- Power Dissipation Per Pole:
- 24 W AC-1 || 7.9 W AC-3 || 7.9 W AC-3e
- Hold-In Power Consumption In W:
- 2.4-5.1 W 20°C
- Environmental Disclosure:
- ENVPEP060301EN
- Sustainable Packaging:
- Yes
- Country of Origin:
- Czechia
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Signaling Circuit Frequency:
- 25...400 Hz
- Poles Description:
- 3P
- Inrush Power In W:
- 270-365 W 20°C)