Schneider Electric

Schneider Electric LC1D115M5 IEC contactor, TeSys Deca, nonreversing, 115A, 75HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D115M5
MPN:
LC1D115M5
Condition:
New
Weight:
2.5 kg
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 115 A (at <60°C) at <= 440 V AC AC-3e for power circuit
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Heat Dissipation:
3-8 W at 50 Hz
Inrush Power In Va:
300-300 VA 50 Hz cos phi 0.8 (at 20°C)
Compatibility Code:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Irms Rated Making Capacity:
1260 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Environmental Disclosure:
ENVPEP060301EN
Contactor Application:
motor control || resistive load
Eu Rohs Directive:
Compliant with Exemptions
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Protective Cover:
with
Maximum Operating Rate:
2400 cyc/h 60°C
Pollution Degree:
3
Flame Retardance:
V1 conforming to UL 94
Pvc Free:
Yes
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mounting Support:
rail || plate
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Signaling Circuit Frequency:
25...400 Hz
Circularity Profile:
ENVEOLI100405EN
[Uc] Control Circuit Voltage:
220 V AC 50 Hz
Minimum Switching Current:
5 mA for Signaling circuit
Poles Description:
3P
Width:
120 mm
Operating Time:
6...20 ms opening || 20...50 ms closing
Minimum Switching Voltage:
17 V for Signaling circuit
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50 Hz || 0.85...1.1 Uc -40-55°C operational AC 50 Hz || 1...1.1 Uc 55-70°C operational AC 50 Hz
Maximum Horse Power Rating:
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Net Weight:
2.5 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Product Certifications:
UL || CSA || CCC || UKCA || CE || EAC || Marine
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Range:
TeSys
Product Or Component Type:
contactor
Mercury Free:
Yes
Control Circuit Type:
AC 50 Hz
Mechanical Durability:
8 Mcycles
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Operating Altitude:
0...9842.52 ft (0...3000 m)
$479.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 115A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 30HP at 200 to 208VAC, 40HP at 240VAC, 75HP at 480VAC and 100HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with a 600VAC up to 250A circuit breaker, this contactor can have a SCCR up to 50kA. When used with 600VAC Class J or CC fuses up to 250A, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose