Schneider Electric LC1D123B7 IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style
Schneider Electric
$142.80
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Compatibility Code:
- LC1D
- Fire Resistance:
- 850°C IEC 60695-2-1
- Circularity Profile:
- ENVEOLI1501004
- Pole Contact Composition:
- 3 NO
- Warranty:
- 18 months
- Control Circuit Type:
- AC 50/60 Hz
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Pvc Free:
- Yes
- Eu Rohs Directive:
- Compliant
- Weight:
- 0.325 kg
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Motor Power Kw:
- 3 kW at 220...230 V AC 50/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 5.5 kW at 415 V AC 50/60 Hz (AC-3) || 5.5 kW at 440 V AC 50/60 Hz (AC-3) || 7.5 kW at 500 V AC 50/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 3 kW a
- Average Impedance:
- 2.5 mOhm - Ith 16 A 50 Hz for power circuit
- Connections - Terminals:
- power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable s
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mechanical Durability:
- 15 Mcycles
- Range Of Product:
- TeSys Deca
- Environmental Disclosure:
- ENVPEP1501004
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Irms Rated Making Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Device Short Name:
- LC1D
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Contactor Application:
- motor control || resistive load
- Country of Origin:
- France
- Depth:
- 86 mm
- Coil Technology:
- without built-in suppressor module
- Toxic Heavy Metal Free:
- Yes
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- [Icw] Rated Short-Time Withstand Current:
- 105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Power Dissipation Per Pole:
- 0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
- Rohs Exemption Information:
- Yes
- Product Or Component Type:
- contactor
- Utilisation Category:
- AC-1 || AC-4 || AC-3 || AC-3e
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Pollution Degree:
- 3
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Protective Treatment:
- THIEC 60068-2-30
- Signaling Circuit Frequency:
- 25...400 Hz
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold