Schneider Electric

Schneider Electric LC1D123FE7 IEC contactor, TeSys D, nonreversing, 12A, 7.5HP at 480VAC, 3 phase, 3 pole, 3 NO, 115VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D123FE7
MPN:
LC1D123FE7
Condition:
New
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Country of Origin:
Indonesia
Product Or Component Type:
contactor
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Poles Description:
3P
[Uc] Control Circuit Voltage:
115 V AC 50/60 Hz
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Protective Cover:
with
Pvc Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Mounting Support:
rail || plate
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Contactor Application:
resistive load || motor control
Power Dissipation Per Pole:
0.36 W AC-3 || 1.56 W AC-1 || 0.36 W AC-3e
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Eu Rohs Directive:
Compliant
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Pole Contact Composition:
3 NO
Ip Degree Of Protection:
IP20 front face IEC 60529
Minimum Switching Current:
5 mA for Signaling circuit
Weight:
0.325 kg
Electrical Durability:
2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
Flame Retardance:
V1 conforming to UL 94
Mechanical Durability:
15 Mcycles
Rohs Exemption Information:
Yes
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Operating Time:
12...22 ms closing || 4...19 ms opening
Toxic Heavy Metal Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Connections - Terminals:
power circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 1 2.5-2.5 mm² - cable s
Sustainable Offer Status:
Green Premium product
Overvoltage Category:
III
[Ie] Rated Operational Current:
16 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Motor Power Kw:
3 kW at 220...230 V AC 50/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) || 7.5 kW at 500 V AC 50/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 3.7 kW at 400 V AC 50/60 Hz (AC-4) ||
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Signaling Circuit Frequency:
25...400 Hz
Protective Treatment:
THIEC 60068-2-30
Depth:
86 mm
Maximum Operating Rate:
3600 cyc/h 60°C
Mercury Free:
Yes
$119.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose