Pole Contact Composition:
3 NO
Minimum Switching Voltage:
17 V for Signaling circuit
Overvoltage Category:
III
Insulation Resistance:
> 10 MOhm for Signaling circuit
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 9.5 mm
Device Short Name:
LC1D
Range Of Product:
TeSys Deca
Operating Time:
77±15 % ms closing || 25±20 % ms opening
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Coil Technology:
with integral suppression device
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pvc Free:
Yes
Time Constant:
37 ms
Hold-In Power Consumption In W:
4-4 W 20°C
Rohs Exemption Information:
Yes
Poles Description:
3P
Protective Cover:
with
Mounting Support:
rail || plate
Electrical Durability:
2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
Mechanical Durability:
30 Mcycles
Warranty:
18 months
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Motor Power Kw:
3 kW at 220/230 V AC 50 Hz (AC-3) || 5.5 kW at 380/400 V AC 50 Hz (AC-3) || 5.5 kW at 415 V AC 50 Hz (AC-3) || 5.5 kW at 440 V AC 50 Hz (AC-3) || 7.5 kW at 500 V AC 50 Hz (AC-3) || 7.5 kW at 660/690 V AC 50 Hz (AC-3) || 3 kW at 220/230 V AC 50 Hz (AC
Control Circuit Type:
DC low consumption
Net Weight:
0.325 kg
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Power Dissipation Per Pole:
1.56 W AC-1 || 0.36 W AC-3 || 0.36 W AC-3e
Auxiliary Contact Composition:
1 NO + 1 NC
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Compatibility Code:
LC1D
Width:
45 mm
Environmental Disclosure:
ENVPEP2205004
Product Or Component Type:
contactor
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Minimum Switching Current:
5 mA for Signaling circuit
Product Certifications:
IEC || CCC || EAC || UA || TR || UKCA
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Climatic Withstand:
IACS E10 || IEC 60947-1 Annex Q category D
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Contactor Application:
motor control || resistive load
Depth:
95 mm
$187.68

Description

This TeSys D contactor has been designed for motor control in railway applications. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200 to 208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. Contactor is supplied with a low consumption 72 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.07 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Contactor is also compliant with the railway European standard EN 45545 R22HL3.