Schneider Electric LC1D1286BLS207 IEC contactor, TeSys D, nonreversing, 25A resistive, 4 pole, 2 NO and 2 NC, low consumption 24VDC coil, open style
Schneider Electric
$216.72
This TeSys D contactor has been designed for motor control in railway applications. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 1.16 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Contactor is also compliant with the railway European standard EN 45545 R22HL3.
- Product Or Component Type:
- contactor
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 25 A (at 60°C) for power circuit
- Tightening Torque:
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Environmental Disclosure:
- ENVPEP2205004
- Climatic Withstand:
- IACS E10 || IEC 60947-1 Annex Q category D
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Operating Time:
- 77±15 % ms closing || 25±20 % ms opening
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Height:
- 85 mm
- Mechanical Durability:
- 30 Mcycles
- [Ie] Rated Operational Current:
- 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit
- Product Certifications:
- IEC || CCC || EAC || UA || TR || UKCA || CB
- Mounting Support:
- plate || rail
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Power Dissipation Per Pole:
- 1.56 W AC-1 || 0.36 W AC-3
- Coil Technology:
- with integral suppression device
- Mercury Free:
- Yes
- Rated Breaking Capacity:
- 250 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Overvoltage Category:
- III
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Fire Resistance:
- 850°C IEC 60695-2-1
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ambient Air Temperature For Storage:
- -60-80°C
- Contactor Application:
- resistive load
- Protective Cover:
- with
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Range Of Product:
- TeSys Deca
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Compatibility Code:
- LC1D
- Time Constant:
- 37 ms
- Hold-In Power Consumption In W:
- 4-4 W 20°C
- Pvc Free:
- Yes
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || EN 45545: R22 HL3 || EN 45545: R26 HL3 || DIN 5510-2
- Control Circuit Type:
- DC low consumption
- Poles Description:
- 4P
- Eu Rohs Directive:
- Compliant with Exemptions
- Device Short Name:
- LC1D
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Circularity Profile:
- N/A
- Control Circuit Voltage Limits:
- 0.1...0.25 Uc -40-70°C drop-out DC || 0.7...1.25 Uc -40-70°C operational DC