SKU:
LC1D128B7
MPN:
LC1D128B7
Condition:
New
Net Weight:
0.365 kg
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Product Or Component Type:
contactor
Operating Time:
12...22 ms closing || 4...19 ms opening
Control Circuit Type:
AC 50/60 Hz
Width:
45 mm
Heat Dissipation:
2-3 W at 50/60 Hz
Country of Origin:
United States
Power Dissipation Per Pole:
1.56 W AC-1
Auxiliary Contact Composition:
1 NO + 1 NC
Coil Technology:
without built-in suppressor module
Insulation Resistance:
> 10 MOhm for Signaling circuit
Poles Description:
4P
Warranty:
18 months
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Altitude:
0...9842.52 ft (0...3000 m)
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Protective Treatment:
THIEC 60068-2-30
Minimum Switching Current:
5 mA for Signaling circuit
Electrical Durability:
0.8 Mcycles 25 A AC-1 <= 440 V
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Compatibility Code:
LC1D
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Ip Degree Of Protection:
IP20 front face IEC 60529
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Toxic Heavy Metal Free:
Yes
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Pole Contact Composition:
2 NO + 2 NC
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Flame Retardance:
V1 conforming to UL 94
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Overvoltage Category:
III
Minimum Switching Voltage:
17 V for Signaling circuit
Eu Rohs Directive:
Compliant
Protective Cover:
with
Fire Resistance:
850°C IEC 60695-2-1
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Contactor Application:
resistive load
$165.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.