Schneider Electric

Schneider Electric LC1D128EL IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 2 NO and 2 NC, low consumption 48VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D128EL
MPN:
LC1D128EL
Condition:
New
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition:
1 NO + 1 NC
Country of Origin:
France
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Protective Cover:
with
[Icw] Rated Short-Time Withstand Current:
105 A 40°C - 10 s for power circuit || 210 A 40°C - 1 s for power circuit || 30 A 40°C - 10 min for power circuit || 61 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms fo
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Tightening Torque:
power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || contro
Operating Altitude:
0...9842.52 ft (0...3000 m)
Maximum Operating Rate:
3600 cyc/h 60°C
Width:
45 mm
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Coil Technology:
built-in bidirectional peak limiting diode suppressor
[Ith] Conventional Free Air Thermal Current:
25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Mechanical Durability:
30 Mcycles
Weight:
0.525 kg
Eu Rohs Directive:
Compliant with Exemptions
Pole Contact Composition:
2 NO + 2 NC
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Time Constant:
40 ms
Compatibility Code:
LC1D
Rohs Exemption Information:
Yes
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Circularity Profile:
ENVEOLI1102030EN
Ip Degree Of Protection:
IP20 front face IEC 60529
Protective Treatment:
THIEC 60068-2-30
Product Or Component Type:
contactor
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Control Circuit Type:
DC low consumption
Signaling Circuit Frequency:
25...400 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Mercury Free:
Yes
Poles Description:
4P
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
[Uc] Control Circuit Voltage:
48 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Warranty:
18 months
Range Of Product:
TeSys Deca
Overvoltage Category:
III
Height:
85 mm
Contactor Application:
resistive load
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Pollution Degree:
3
Depth:
99 mm
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Device Short Name:
LC1D
$206.40

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a low consumption 48 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 1.16 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose