Schneider Electric

Schneider Electric LC1D12BNE IEC contactor, TeSys Deca Green, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D12BNE
MPN:
LC1D12BNE
Condition:
New
Compatibility Code:
LC1D
Coil Technology:
built-in bidirectional peak limiting
Protective Cover:
with
Pollution Degree:
3
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Hold-In Power Consumption In W:
0.6-0.6 W 20°C
Insulation Resistance:
> 10 MOhm for Signaling circuit
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 40 A gG at <= 690 V coordination type 1 for power circuit || 25 A gG at <= 690 V coordination type 2 for power circuit
Overvoltage Category:
III
Product Or Component Type:
contactor
Range:
TeSys || TeSys Deca
Utilisation Category:
AC-3 || AC-1 || AC-3e
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Halogen Content Performance:
Halogen free plastic parts & cables product
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Auxiliary Contact Composition:
1 NO + 1 NC
Net Weight:
0.373 kg
Mounting Support:
rail || plate
Flame Retardance:
V1 conforming to UL 94
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC-3e for power circuit
Inrush Power In Va:
15-15 VA 50/60 Hz (at 20°C)
Hold-In Power Consumption In Va:
0.9-0.9 VA 50/60 Hz (at 20°C)
Range Of Product:
TeSys Deca
Depth:
86 mm
Circularity Profile:
ENVEOLI1609001EN
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Device Short Name:
LC1D
Heat Dissipation:
0.6-0.6 W at 50/60 Hz
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || power circuit 1.7 N.m screw clamp terminals Philips No 2 || power
Operating Time:
45...55 ms closing || 20...90 ms opening
Maximum Operating Rate:
3600 cyc/h 60°C
Electrical Durability:
2.3 Mcycles 11 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2.3 Mcycles 11 A AC-3e <= 440 V
Operating Altitude:
0...9842.52 ft (0...3000 m)
Minimum Switching Current:
5 mA for Signaling circuit
[Uc] Control Circuit Voltage:
24...60 V AC 50/60 Hz || 24...60 V DC
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Ip Degree Of Protection:
IP20 front face IEC 60529
Eu Rohs Directive:
Compliant with Exemptions
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Power Dissipation Per Pole:
1.56 W AC-1 || 0.36 W AC-3 || 0.36 W AC-3e
Contactor Application:
resistive load || motor control
Signaling Circuit Frequency:
25...400 Hz
Irms Rated Making Capacity:
250 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Minimum Switching Voltage:
17 V for Signaling circuit
$47.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose