Schneider Electric

Schneider Electric LC1D12F7 IEC contactor, TeSys Deca, nonreversing, 12A, 7.5HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D12F7
MPN:
LC1D12F7
Condition:
New
Mercury Free:
Yes
Maximum Horse Power Rating:
0.5 hp at 115 V AC 50/60 Hz for 1 phase motors || 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 3 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 7.5 hp at 460/480 V AC 50/60 Hz for 3 phase
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
[Ie] Rated Operational Current:
25 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Operating Time:
12...22 ms closing || 4...19 ms opening
Electrical Durability:
2 Mcycles 12 A AC-3 <= 440 V || 0.8 Mcycles 25 A AC-1 <= 440 V || 2 Mcycles 12 A AC-3e <= 440 V
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Coil Technology:
without built-in suppressor module
Minimum Switching Current:
5 mA for Signaling circuit
Connections - Terminals:
power circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || power circuit: screw clamp terminals 1 1-4 mm² - cable
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Pollution Degree:
3
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Weight:
0.325 kg
Poles Description:
3P
Pole Contact Composition:
3 NO
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Mechanical Durability:
15 Mcycles
Insulation Resistance:
> 10 MOhm for Signaling circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Sustainable Offer Status:
Green Premium product
Minimum Switching Voltage:
17 V for Signaling circuit
Device Short Name:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Compatibility Code:
LC1D
Heat Dissipation:
2-3 W at 50/60 Hz
Depth:
86 mm
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Signaling Circuit Frequency:
25...400 Hz
Motor Power Kw:
3 kW at 220...230 V AC 50/60 Hz (AC-3) || 5.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 5.5 kW at 415...440 V AC 50/60 Hz (AC-3) || 7.5 kW at 500 V AC 50/60 Hz (AC-3) || 7.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 3.7 kW at 400 V AC 50/60 Hz (AC-4) ||
Average Impedance:
2.5 mOhm - Ith 25 A 50 Hz for power circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Rated Breaking Capacity:
250 A at 440 V for power circuit conforming to IEC 60947
Country of Origin:
Indonesia
Utilisation Category:
AC-3 || AC-4 || AC-1 || AC-3e
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Overvoltage Category:
III
Product Certifications:
GL || BV || DNV || LROS (Lloyds register of shipping) || RINA || UL || CCC || CSA || GOST || UKCA || CB
[Ith] Conventional Free Air Thermal Current:
25 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Net Weight:
0.325 kg
$142.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 12A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 3HP at 200-208VAC, 3HP at 240VAC, 7.5HP at 480VAC and 10HP at 600VAC three phase. Contactor is also rated for 0.5HP at 115VAC and 2HP at 240VAC single phase. When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 30A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.72 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose