Schneider Electric

Schneider Electric LC1D1506B7 IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D1506B7
MPN:
LC1D1506B7
Condition:
New
Product Or Component Type:
contactor
Auxiliary Contact Composition:
1 NO + 1 NC
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Motor Power Kw:
40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
Sustainable Offer Status:
Green Premium product
Tightening Torque:
control circuit 1.2 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.2 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 12 N.m lugs-ring terminals hexagonal 13 mm M8 || power circuit 12 N.m bars hexagonal 13 mm M8 || control c
[Icw] Rated Short-Time Withstand Current:
250 A 40°C - 10 min for power circuit || 580 A 40°C - 1 min for power circuit || 1200 A 40°C - 10 s for power circuit || 1400 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 m
Weight:
2.5 kg
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Mechanical Durability:
8 Mcycles
Product Certifications:
UL || CCC || CSA || CE || UKCA || Marine || EAC
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Device Short Name:
LC1D
Pole Contact Composition:
3 NO
Ip Degree Of Protection:
IP20 front face IEC 60529
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Minimum Switching Current:
5 mA for Signaling circuit
Flame Retardance:
V1 conforming to UL 94
Warranty:
18 months
Inrush Power In Va:
280-350 VA 60 Hz cos phi 0.9 (at 20°C) || 280-350 VA 50 Hz cos phi 0.9 (at 20°C)
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Protective Cover:
with
Minimum Switching Voltage:
17 V for Signaling circuit
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Depth:
136 mm
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Compatibility Code:
LC1D
Environmental Disclosure:
ENVPEP060301EN
Utilisation Category:
AC-3 || AC-1 || AC-4 || AC-3e
Signaling Circuit Frequency:
25...400 Hz
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Circularity Profile:
ENVEOLI100405EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
Net Weight:
2.5 kg
Contactor Application:
motor control || resistive load
Range Of Product:
TeSys Deca
Overvoltage Category:
III
Control Circuit Type:
AC 50/60 Hz
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Maximum Operating Rate:
1200 cyc/h 60°C
Poles Description:
3P
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose