TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Eu Rohs Directive:
- Compliant with Exemptions
- Sustainable Packaging:
- Yes
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
- Contactor Application:
- motor control || resistive load
- Inrush Power In W:
- 270-365 W 20°C)
- Utilisation Category:
- AC-3 || AC-1 || AC-4 || AC-3e
- Product Certifications:
- UL || CCC || CSA || CE || UKCA || Marine || EAC
- Safety Reliability Level:
- B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Circularity Profile:
- ENVEOLI100405EN
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Tightening Torque:
- control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Fire Resistance:
- 850°C IEC 60695-2-1
- Net Weight:
- 2.5 kg
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Overvoltage Category:
- III
- Motor Power Kw:
- 40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
- Height:
- 158 mm
- Width:
- 120 mm
- Product Or Component Type:
- contactor
- [Uc] Control Circuit Voltage:
- 110 V DC
- Protective Treatment:
- THIEC 60068-2-30
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Compatibility Code:
- LC1D
- Poles Description:
- 3P
- Range Of Product:
- TeSys Deca
- Rohs Exemption Information:
- Yes
- Control Circuit Voltage Limits:
- 0.75...1.2 Uc -40-55°C operational DC || 0.15...0.4 Uc -40-70°C drop-out DC || 1...1.2 Uc 55-70°C operational DC
- Weight:
- 2.5 kg
- Environmental Disclosure:
- ENVPEP060301EN
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Range:
- TeSys
- Warranty:
- 18 months
- Mechanical Durability:
- 8 Mcycles
- Mounting Support:
- rail || plate
- Control Circuit Type:
- DC standard
- Sustainable Offer Status:
- Green Premium product
- Pvc Free:
- Yes
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Maximum Operating Rate:
- 1200 cyc/h 60°C
- Device Short Name:
- LC1D
- Mercury Free: