Schneider Electric LC1D150LE7 IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 50/60Hz coil, open
Schneider Electric
$696.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 208 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Compatibility Code:
- LC1D
- Country of Origin:
- United States
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Signaling Circuit Frequency:
- 25...400 Hz
- Fire Resistance:
- 850°C IEC 60695-2-1
- Product Certifications:
- UL || CCC || CSA || CE || UKCA || Marine || EAC
- Mechanical Durability:
- 8 Mcycles
- Motor Power Kw:
- 40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Pole Contact Composition:
- 3 NO
- Rohs Exemption Information:
- Yes
- Safety Reliability Level:
- B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
- [Icw] Rated Short-Time Withstand Current:
- 250 A 40°C - 10 min for power circuit || 580 A 40°C - 1 min for power circuit || 1200 A 40°C - 10 s for power circuit || 1400 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 m
- Tightening Torque:
- control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Climatic Withstand:
- IACS E10 exposure to damp heat
- Sustainable Offer Status:
- Green Premium product
- Eu Rohs Directive:
- Compliant with Exemptions
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Pollution Degree:
- 3
- Device Short Name:
- LC1D
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ith] Conventional Free Air Thermal Current:
- 200 A (at 60°C) for power circuit
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
- Contactor Application:
- resistive load || motor control
- [Ie] Rated Operational Current:
- 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Mounting Support:
- rail || plate
- Poles Description:
- 3P
- Environmental Disclosure:
- ENVPEP060301EN
- Control Circuit Voltage Limits:
- 0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
- Power Dissipation Per Pole:
- 24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
- Utilisation Category:
- AC-1 || AC-4 || AC-3 || AC-3e
- Heat Dissipation:
- 3-4.5 W at 50/60 Hz
- Pvc Free:
- Yes
- Sustainable Packaging:
- Yes
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
- Depth:
- 136 mm
- Range:
- TeSys
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Width:
- 120 mm
- Overvoltage Category:
- III
- [Ue] Rated Operational Voltage:
- power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
- Average Impedance:
- 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Electrical Durability:
- 0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Hold-In Power Consumption In Va:
- 2-18 VA 60 Hz cos phi 0.9 (at 20°C) || 2-18 VA 50 Hz cos phi 0.9 (at 20°C)