Schneider Electric

Schneider Electric LC1D150P7 IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 230VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D150P7
MPN:
LC1D150P7
Condition:
New
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Mechanical Durability:
8 Mcycles
Product Or Component Type:
contactor
Operating Altitude:
0...9842.52 ft (0...3000 m)
Range:
TeSys
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pole Contact Composition:
3 NO
Pvc Free:
Yes
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 315 A gG at <= 690 V coordination type 1 for power circuit || 250 A gG at <= 690 V coordination type 2 for power circuit
Eu Rohs Directive:
Compliant with Exemptions
Electrical Durability:
0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
Poles Description:
3P
Country of Origin:
Czechia
Flame Retardance:
V1 conforming to UL 94
Maximum Operating Rate:
1200 cyc/h 60°C
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Product Certifications:
UL || CCC || CSA || CE || UKCA || Marine || EAC
Insulation Resistance:
> 10 MOhm for Signaling circuit
Warranty:
18 months
Heat Dissipation:
3-4.5 W at 50/60 Hz
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Sustainable Offer Status:
Green Premium product
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
Motor Power Kw:
40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
Overvoltage Category:
III
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Mercury Free:
Yes
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Hold-In Power Consumption In Va:
2-18 VA 60 Hz cos phi 0.9 (at 20°C) || 2-18 VA 50 Hz cos phi 0.9 (at 20°C)
Range Of Product:
TeSys Deca
Operating Time:
20...35 ms closing || 40...75 ms opening
Minimum Switching Voltage:
17 V for Signaling circuit
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Compatibility Code:
LC1D
Control Circuit Type:
AC 50/60 Hz standard
Minimum Switching Current:
5 mA for Signaling circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Protective Treatment:
THIEC 60068-2-30
Depth:
136 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Power Dissipation Per Pole:
24 W AC-1 || 13.5 W AC-3 || 13.5 W AC-3e
Device Short Name:
LC1D
Climatic Withstand:
IACS E10 exposure to damp heat
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose