Schneider Electric

Schneider Electric LC1D150R7 IEC contactor, TeSys Deca, nonreversing, 150A, 100HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 440VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D150R7
MPN:
LC1D150R7
Condition:
New
Flame Retardance:
V1 conforming to UL 94
Utilisation Category:
AC-3 || AC-4 || AC-1 || AC-3e
Compatibility Code:
LC1D
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Net Weight:
2.5 kg
Overvoltage Category:
III
Mechanical Durability:
8 Mcycles
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Width:
120 mm
Climatic Withstand:
IACS E10 exposure to damp heat
Product Or Component Type:
contactor
Sustainable Packaging:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Height:
158 mm
Ip Degree Of Protection:
IP20 front face IEC 60529
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 1660 A at 440 V for power circuit conforming to IEC 60947
Operating Time:
20...35 ms closing || 40...75 ms opening
Depth:
136 mm
[Uc] Control Circuit Voltage:
440 V AC 50/60 Hz
Circularity Profile:
ENVEOLI100405EN
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Minimum Switching Current:
5 mA for Signaling circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Maximum Horse Power Rating:
40 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 50 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 100 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 125 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Hold-In Power Consumption In Va:
2-18 VA 60 Hz cos phi 0.9 (at 20°C) || 2-18 VA 50 Hz cos phi 0.9 (at 20°C)
Contactor Application:
resistive load || motor control
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Pole Contact Composition:
3 NO
Mercury Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Motor Power Kw:
40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
Poles Description:
3P
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Sustainable Offer Status:
Green Premium product
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Rated Breaking Capacity:
1400 A at 440 V for power circuit conforming to IEC 60947
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Environmental Disclosure:
ENVPEP060301EN
Pollution Degree:
3
Signaling Circuit Frequency:
25...400 Hz
Protective Cover:
with
Country of Origin:
Czechia
[Ith] Conventional Free Air Thermal Current:
200 A (at 60°C) for power circuit
Range:
TeSys
Minimum Switching Voltage:
17 V for Signaling circuit
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 440 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose