Operating Altitude:
0...9842.52 ft (0...3000 m)
Pole Contact Composition:
3 NO
Average Impedance:
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Fire Resistance:
850°C IEC 60695-2-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Warranty:
18 months
Pvc Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Eu Rohs Directive:
Compliant with Exemptions
Product Or Component Type:
contactor
Tightening Torque:
control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Ip Degree Of Protection:
IP20 front face IEC 60529
Circularity Profile:
ENVEOLI100405EN
Weight:
2.5 kg
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || IEC 60947-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
[Ie] Rated Operational Current:
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 150 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Mechanical Durability:
8 Mcycles
Control Circuit Type:
AC 50/60 Hz
Inrush Power In Va:
280-350 VA 60 Hz cos phi 0.9 (at 20°C) || 280-350 VA 50 Hz cos phi 0.9 (at 20°C)
Safety Reliability Level:
B10d = 684932 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Maximum Operating Rate:
1200 cyc/h 60°C
Net Weight:
2.5 kg
[Ue] Rated Operational Voltage:
power circuit <= 1000 V AC 25...400 Hz || power circuit <= 300 V DC
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Mercury Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Power Kw:
40 kW at 220...230 V AC 50/60 Hz (AC-3) || 75 kW at 380...400 V AC 50/60 Hz (AC-3) || 80 kW at 415...440 V AC 50/60 Hz (AC-3) || 90 kW at 500 V AC 50/60 Hz (AC-3) || 100 kW at 660...690 V AC 50/60 Hz (AC-3) || 75 kW at 1000 V AC 50/60 Hz (AC-3) || 22
[Uc] Control Circuit Voltage:
240 V AC 50/60 Hz
Protective Cover:
with
Environmental Disclosure:
ENVPEP060301EN
Protective Treatment:
THIEC 60068-2-30
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)
Poles Description:
3P
Heat Dissipation:
3-4.5 W at 50/60 Hz
Utilisation Category:
AC-3 || AC-4 || AC-1 || AC-3e
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-2.5 mm² -
Minimum Switching Voltage:
17 V for Signaling circuit
Insulation Resistance:
> 10 MOhm for Signaling circuit
Country of Origin:
France
Compatibility Code:
LC1D
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Device Short Name:
LC1D
Electrical Durability:
0.85 Mcycles 150 A AC-3 <= 440 V || 1 Mcycles 200 A AC-1 <= 440 V || 0.85 Mcycles 150 A AC-3e <= 440 V
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Control Circuit Voltage Limits:
0.3...0.5 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55°C operational AC 50/60 Hz || 1...1.15 Uc 55-70°C operational AC 50/60 Hz
Sustainable Packaging:
Yes
$696.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 150A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 40HP at 200 to 208VAC, 50HP at 240VAC, 100HP at 480VAC and 125HP at 600VAC three phase. When used with a 480VAC up to 250A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 300A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 4.72 inches wide and 5.35 inches deep. It weighs 5.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.