TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200 to 208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Uc] Control Circuit Voltage:
- 48 V AC 50/60 Hz
- Contactor Application:
- motor control || resistive load
- Power Dissipation Per Pole:
- 2.5 W AC-1 || 0.8 W AC-3 || 0.8 W AC-3e
- Country of Origin:
- Indonesia
- Maximum Horse Power Rating:
- 1 hp at 115 V AC 50/60 Hz for 1 phase motors || 3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 5 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 460/480 V AC 50/60 Hz for 3 phase mot
- Fire Resistance:
- 850°C IEC 60695-2-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Net Weight:
- 0.33 kg
- Eu Rohs Directive:
- Compliant
- Circularity Profile:
- ENVEOLI1501004
- Average Impedance:
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Motor Power Kw:
- 4 kW at 220...230 V AC 50/60 Hz (AC-3) || 7.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 9 kW at 415...440 V AC 50/60 Hz (AC-3) || 10 kW at 500 V AC 50/60 Hz (AC-3) || 10 kW at 660...690 V AC 50/60 Hz (AC-3) || 4 kW at 400 V AC 50/60 Hz (AC-4) || 4 kW a
- Flame Retardance:
- V1 conforming to UL 94
- Depth:
- 86 mm
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Connections - Terminals:
- control circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 1 4-4 mm² - cable sti
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Environmental Disclosure:
- ENVPEP1501004
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Overvoltage Category:
- III
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Electrical Durability:
- 1.65 Mcycles 18 A AC-3 <= 440 V || 1 Mcycles 32 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
- Height:
- 99 mm
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Rohs Exemption Information:
- Yes
- Pvc Free:
- Yes
- Warranty:
- 18 months
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Weight:
- 0.33 kg
- Coil Technology:
- without built-in suppressor module
- Signaling Circuit Frequency:
- 25...400 Hz
- Control Circuit Type:
- AC 50/60 Hz
- Sustainable Offer Status:
- Green Premium product
- Mechanical Durability:
- 15 Mcycles
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Device Short Name:
- LC1D
- Rated Breaking Capacity:
- 300 A at 440 V for power circuit conforming to IEC 60947
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Product Or Component Type:
- contactor
- Product Certifications:
- DNV || UL || LROS (Lloyds register of shipping) || GOST || CCC || BV || CSA || RINA || GL || UKCA
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Compatibility Code:
- LC1D
- Utilisation Category:
- AC-4 || AC-1 || AC-3 || AC-3e
- [Ie] Rated Operational Current:
- 18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Mercury Free:
- Yes