Schneider Electric LC1D188E7 IEC contactor, TeSys Deca, nonreversing, 32A resistive, 4 pole, 2 NO and 2 NC, 48VAC 50/60Hz coil, open style
Schneider Electric
$194.40
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 32A resistive load rating. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Protective Cover:
- with
- Signaling Circuit Frequency:
- 25...400 Hz
- Mechanical Durability:
- 15 Mcycles
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
- Net Weight:
- 0.425 kg
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit
- Fire Resistance:
- 850°C IEC 60695-2-1
- Pole Contact Composition:
- 2 NO + 2 NC
- Sustainable Offer Status:
- Green Premium product
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Rohs Exemption Information:
- Yes
- Compatibility Code:
- LC1D
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Circularity Profile:
- ENVEOLI1501004
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Power Dissipation Per Pole:
- 2.5 W AC-1
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Mercury Free:
- Yes
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Contactor Application:
- resistive load
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Environmental Disclosure:
- ENVPEP1501004
- Pollution Degree:
- 3
- Protective Treatment:
- THIEC 60068-2-30
- Country of Origin:
- Indonesia
- Warranty:
- 18 months
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Toxic Heavy Metal Free:
- Yes
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Coil Technology:
- without built-in suppressor module
- Product Or Component Type:
- contactor
- Utilisation Category:
- AC-1 || AC-3 || AC-3e || AC-4
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-60°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz
- [Uc] Control Circuit Voltage:
- 48 V AC 50/60 Hz
- Control Circuit Type:
- AC 50/60 Hz
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Eu Rohs Directive:
- Compliant
- Range Of Product:
- TeSys Deca
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 50 A gG at <= 690 V coordination type 1 for power circuit || 35 A gG at <= 690 V coordination type 2 for power circuit
- Poles Description:
- 4P