Schneider Electric

Schneider Electric LC1D18BNE IEC contactor, TeSys Deca Green, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D18BNE
MPN:
LC1D18BNE
Condition:
New
Mechanical Durability:
15 Mcycles
Overvoltage Category:
III
Fire Resistance:
850°C IEC 60695-2-1
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Depth:
86 mm
Mercury Free:
Yes
[Ie] Rated Operational Current:
18 A (at <60°C) at <= 440 V AC-3 for power circuit || 32 A (at <60°C) at <= 440 V AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC-3e for power circuit
Coil Technology:
built-in bidirectional peak limiting
Environmental Disclosure:
ENVPEP1609001EN
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Warranty:
18 months
Electrical Durability:
2.2 Mcycles 15 A AC-3 <= 440 V || 0.9 Mcycles 32 A AC-1 <= 440 V || 2.2 Mcycles 15 A AC-3e <= 440 V
Maximum Horse Power Rating:
1 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 5 hp at 200/208 V AC 60 Hz for 3 phase motors || 5 hp at 230/240 V AC 60 Hz for 3 phase motors || 10 hp at 460/480 V AC 60 Hz for 3 phase motors || 15 hp at
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Range:
TeSys || TeSys Deca
[Uc] Control Circuit Voltage:
24...60 V AC 50/60 Hz || 24...60 V DC
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 32 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant with Exemptions
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC || 0.8...1.1 Uc -40-60°C operational DC || 1...1.1 Uc 60-70°C operational AC/DC
Heat Dissipation:
0.6-0.6 W at 50/60 Hz
Height:
77 mm
Insulation Resistance:
> 10 MOhm for Signaling circuit
Weight:
0.378 kg
Pollution Degree:
3
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Protective Cover:
with
Poles Description:
3P
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Compatibility Code:
LC1D
Maximum Operating Rate:
3600 cyc/h 60°C
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Country of Origin:
United States
Hold-In Power Consumption In W:
0.6-0.6 W 20°C
Rohs Exemption Information:
Yes
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Net Weight:
0.378 kg
Inrush Power In W:
14-14 W 20°C)
Device Short Name:
LC1D
Circularity Profile:
ENVEOLI1609001EN
Hold-In Power Consumption In Va:
0.9-0.9 VA 50/60 Hz (at 20°C)
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame Retardance:
V1 conforming to UL 94
Operating Altitude:
0...9842.52 ft (0...3000 m)
$57.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.83 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.