Schneider Electric

Schneider Electric LC1D18F7TQ IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk

(No reviews yet) Write a Review
SKU:
LC1D18F7TQ
MPN:
LC1D18F7TQ
Condition:
New
Range Of Product:
TeSys Deca
Poles Description:
3P
Control Circuit Type:
AC 50/60 Hz
Compatibility Code:
LC1D
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Operating Rate:
3600 cyc/h 60°C
Eu Rohs Directive:
Compliant
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
Connections - Terminals:
control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable sti
Heat Dissipation:
2-3 W at 50/60 Hz for control circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Minimum Switching Current:
5 mA for control circuit
Pvc Free:
Yes
Average Impedance:
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Minimum Switching Voltage:
17 V for control circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Device Short Name:
LC1D
Hold-In Power Consumption In Va:
7-7 VA 50/60 Hz cos phi 0.3 (at 20°C)
Operating Time:
4...19 ms opening || 12...22 ms closing
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Operating Altitude:
9842.52 ft (3000 m) without derating
Insulation Resistance:
> 10 MOhm for control circuit
Sustainable Offer Status:
Green Premium product
Range:
TeSys || TeSys Deca
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Mounting Support:
rail || plate
Maximum Horse Power Rating:
1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to UL || 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motor
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
Standards:
EN/IEC 60947-4-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || IEC 60335-1
Power Dissipation Per Pole:
0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
Toxic Heavy Metal Free:
Yes
Permissible Ambient Air Temperature Around The Device:
-5-60°C || -40-70°C at Uc
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 32 A (at 60°C) for power circuit
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Rohs Exemption Information:
Yes
Quantity Per Set:
set of 10
Circularity Profile:
ENVEOLI1501004
Contactor Application:
resistive load || motor control
Inrush Power In Va:
70-70 VA cos phi 0.75 (at 20°C)
Protective Cover:
with
Flame Retardance:
V1 conforming to UL 94
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
$163.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.