Schneider Electric LC1D18F7TQ IEC contactor, TeSys Deca, nonreversing, 18A, 10HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, bulk
Schneider Electric
$163.20
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Range Of Product:
- TeSys Deca
- Poles Description:
- 3P
- Control Circuit Type:
- AC 50/60 Hz
- Compatibility Code:
- LC1D
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Eu Rohs Directive:
- Compliant
- Irms Rated Making Capacity:
- 140 A AC for control circuit conforming to IEC 60947-5-1 || 300 A at 440 V for power circuit conforming to IEC 60947
- Connections - Terminals:
- control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-4 mm² - cable sti
- Heat Dissipation:
- 2-3 W at 50/60 Hz for control circuit
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
- Minimum Switching Current:
- 5 mA for control circuit
- Pvc Free:
- Yes
- Average Impedance:
- 2.5 mOhm - Ith 32 A 50 Hz for power circuit
- Minimum Switching Voltage:
- 17 V for control circuit
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Device Short Name:
- LC1D
- Hold-In Power Consumption In Va:
- 7-7 VA 50/60 Hz cos phi 0.3 (at 20°C)
- Operating Time:
- 4...19 ms opening || 12...22 ms closing
- Coil Technology:
- without built-in bidirectional peak limiting diode suppressor
- Operating Altitude:
- 9842.52 ft (3000 m) without derating
- Insulation Resistance:
- > 10 MOhm for control circuit
- Sustainable Offer Status:
- Green Premium product
- Range:
- TeSys || TeSys Deca
- [Ie] Rated Operational Current:
- 32 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 18 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Mechanical Robustness:
- shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
- Mounting Support:
- rail || plate
- Maximum Horse Power Rating:
- 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to UL || 1 hp at 115 V AC 50/60 Hz for 1 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motors conforming to CSA || 10 hp at 460/480 V AC 50/60 Hz for 3 phase motor
- [Ui] Rated Insulation Voltage:
- control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-4-1 || power circuit 690 V IEC 60947-4-1
- Standards:
- EN/IEC 60947-4-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || UL 508 || IEC 60335-1
- Power Dissipation Per Pole:
- 0.8 W AC-3 || 2.5 W AC-1 || 0.8 W AC-3e
- Toxic Heavy Metal Free:
- Yes
- Permissible Ambient Air Temperature Around The Device:
- -5-60°C || -40-70°C at Uc
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for control circuit || 32 A (at 60°C) for power circuit
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Rohs Exemption Information:
- Yes
- Quantity Per Set:
- set of 10
- Circularity Profile:
- ENVEOLI1501004
- Contactor Application:
- resistive load || motor control
- Inrush Power In Va:
- 70-70 VA cos phi 0.75 (at 20°C)
- Protective Cover:
- with
- Flame Retardance:
- V1 conforming to UL 94
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)