Connections - Terminals:
control circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 1 4-4 mm² - cable sti
Electrical Durability:
1.65 Mcycles 25 A AC-3 <= 440 V || 1.4 Mcycles 40 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Protective Cover:
with
Mounting Support:
rail || plate
Operating Time:
12...22 ms closing || 4...19 ms opening
Control Circuit Type:
AC 50/60 Hz
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Signaling Circuit Frequency:
25...400 Hz
Product Or Component Type:
contactor
Range Of Product:
TeSys Deca
Utilisation Category:
AC-4 || AC-3 || AC-1 || AC-3e
Weight:
0.37 kg
Net Weight:
0.37 kg
Power Dissipation Per Pole:
3.2 W AC-1 || 1.25 W AC-3 || 1.25 W AC-3e
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contact Composition:
1 NO + 1 NC
Product Certifications:
DNV || UL || CCC || LROS (Lloyds register of shipping) || GL || CSA || RINA || GOST || BV || UKCA
Sustainable Offer Status:
Green Premium product
Operating Altitude:
0...9842.52 ft (0...3000 m)
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
Country of Origin:
France
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Width:
45 mm
Minimum Switching Voltage:
17 V for Signaling circuit
Heat Dissipation:
2-3 W at 50/60 Hz
[Icw] Rated Short-Time Withstand Current:
240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Warranty:
18 months
Compatibility Code:
LC1D
Mechanical Durability:
15 Mcycles
Insulation Resistance:
> 10 MOhm for Signaling circuit
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Device Short Name:
LC1D
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Eu Rohs Directive:
Compliant
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Overvoltage Category:
III
Maximum Operating Rate:
3600 cyc/h 60°C
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Height:
99 mm
Environmental Disclosure:
ENVPEP110229EN
Circularity Profile:
ENVEOLI110229EN
Average Impedance:
2 mOhm - Ith 25 A 50 Hz for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Maximum Horse Power Rating:
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 2 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors || 20 hp at 575/600 V AC 50/60 Hz for 3 phase
Ip Degree Of Protection:
IP20 front face IEC 60529
$181.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.82 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose