Schneider Electric

Schneider Electric LC1D256BLS207 IEC contactor, TeSys D, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D256BLS207
MPN:
LC1D256BLS207
Condition:
New
Utilisation Category:
AC-3 || AC-1 || AC-3e
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Contactor Application:
motor control || resistive load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Circularity Profile:
N/A
Auxiliary Contact Composition:
1 NO + 1 NC
Range:
TeSys || TeSys Deca
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Certifications:
IEC || CCC || EAC || UA || TR || UKCA || CB
Overvoltage Category:
III
Electrical Durability:
1.65 Mcycles 25 A AC-3 <= 440 V || 1.4 Mcycles 40 A AC-1 <= 440 V || 1.65 Mcycles 25 A AC-3e <= 440 V
Rohs Exemption Information:
Yes
Maximum Operating Rate:
3600 cyc/h 60°C
Minimum Switching Voltage:
17 V for Signaling circuit
Control Circuit Type:
DC low consumption
Time Constant:
37 ms
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Pole Contact Composition:
3 NO
Motor Power Kw:
5.5 kW at 220/230 V AC 50 Hz (AC-3) || 11 kW at 380/400 V AC 50 Hz (AC-3) || 11 kW at 415 V AC 50 Hz (AC-3) || 11 kW at 440 V AC 50 Hz (AC-3) || 15 kW at 500 V AC 50 Hz (AC-3) || 15 kW at 660/690 V AC 50 Hz (AC-3) || 5.5 kW at 220/230 V AC 50 Hz (AC-
Environmental Disclosure:
ENVPEP2205004
Inrush Power In W:
4-4 W 20°C)
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || EN 45545: R22 HL3 || EN 45545: R26 HL3 || DIN 5510-2
Fire Resistance:
850°C IEC 60695-2-1
Width:
45 mm
Hold-In Power Consumption In W:
4-4 W 20°C
Minimum Switching Current:
5 mA for Signaling circuit
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Poles Description:
3P
Weight:
0.37 kg
Product Or Component Type:
contactor
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Ambient Air Temperature For Storage:
-60-80°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Insulation Resistance:
> 10 MOhm for Signaling circuit
Protective Cover:
with
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 12 mm
Mercury Free:
Yes
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Operating Altitude:
0...9842.52 ft (0...3000 m)
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4 || power circuit 2.5 N.m lugs-ring terminals flat Ø 6 mm M4
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical Durability:
30 Mcycles
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant with Exemptions
$226.80

Description

This TeSys D contactor has been designed for motor control in railway applications. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.17 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.