Schneider Electric

Schneider Electric LC1D258BL IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 2 NO and 2 NC, low consumption 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D258BL
MPN:
LC1D258BL
Condition:
New
Height:
91 mm
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Poles Description:
4P
Time Constant:
40 ms
Pole Contact Composition:
2 NO + 2 NC
Compatibility Code:
LC1D
Inrush Power In W:
2.4-2.4 W 20°C)
Control Circuit Type:
DC low consumption
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 40 A (at 60°C) for power circuit
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
[Uc] Control Circuit Voltage:
24 V DC
Maximum Operating Rate:
3600 cyc/h 60°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Power Dissipation Per Pole:
3.2 W AC-1
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Contactor Application:
resistive load
Overvoltage Category:
III
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Pvc Free:
Yes
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
Device Short Name:
LC1D
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
Auxiliary Contact Composition:
1 NO + 1 NC
Fire Resistance:
850°C IEC 60695-2-1
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weight:
0.585 kg
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Insulation Resistance:
> 10 MOhm for Signaling circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 450 A at 440 V for power circuit conforming to IEC 60947
Net Weight:
0.585 kg
Signaling Circuit Frequency:
25...400 Hz
[Icw] Rated Short-Time Withstand Current:
240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Protective Treatment:
THIEC 60068-2-30
Pollution Degree:
3
Depth:
107 mm
Operating Time:
77±15 % ms closing || 25±20 % ms opening
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-60°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC
Mechanical Durability:
30 Mcycles
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Sustainable Offer Status:
Green Premium product
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Protective Cover:
with
$306.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.