Schneider Electric

Schneider Electric LC1D258FE7 IEC contactor, TeSys Deca, nonreversing, 40A resistive, 4 pole, 2 NO and 2 NC, 115VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D258FE7
MPN:
LC1D258FE7
Condition:
New
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Rated Breaking Capacity:
450 A at 440 V for power circuit conforming to IEC 60947
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP20 front face IEC 60529
Product Or Component Type:
contactor
Average Impedance:
2 mOhm - Ith 40 A 50 Hz for power circuit
[Uc] Control Circuit Voltage:
115 V AC 50/60 Hz
[Ie] Rated Operational Current:
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Inrush Power In Va:
70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Country of Origin:
Indonesia
Height:
91 mm
Compatibility Code:
LC1D
Contactor Application:
resistive load
Mounting Support:
plate || rail
Insulation Resistance:
> 10 MOhm for Signaling circuit
Product Certifications:
GL || GOST || DNV || CSA || RINA || CCC || UL || LROS (Lloyds register of shipping) || BV || UKCA
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Flame Retardance:
V1 conforming to UL 94
Net Weight:
0.425 kg
[Icw] Rated Short-Time Withstand Current:
240 A 40°C - 10 s for power circuit || 380 A 40°C - 1 s for power circuit || 50 A 40°C - 10 min for power circuit || 120 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Device Short Name:
LC1D
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Auxiliary Contact Composition:
1 NO + 1 NC
Eu Rohs Directive:
Compliant
Minimum Switching Voltage:
17 V for Signaling circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Minimum Switching Current:
5 mA for Signaling circuit
Sustainable Offer Status:
Green Premium product
Pollution Degree:
3
Circularity Profile:
ENVEOLI110229EN
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Coil Technology:
without built-in suppressor module
Poles Description:
4P
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 1.8 N.m screw clamps terminals flat Ø 6 mm || po
Heat Dissipation:
2-3 W at 50/60 Hz
Warranty:
18 months
Depth:
99 mm
Hold-In Power Consumption In Va:
7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
Environmental Disclosure:
ENVPEP110229EN
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Utilisation Category:
AC-1 || AC-3 || AC-3e || AC-4
Fire Resistance:
850°C IEC 60695-2-1
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$246.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 40A resistive load rating. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.13 inches tall, 1.77 inches wide and 3.90 inches deep. It weighs 0.94 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose