Schneider Electric LC1D25BNE IEC contactor, TeSys Deca Green, nonreversing, 25A, 15HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24/60VAC/VDC coil
Schneider Electric
$66.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 25A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200-208VAC, 7.5HP at 240VAC, 15HP at 480VAC and 20HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 60A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 24-60V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.95 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Hold-In Power Consumption In Va:
- 0.9-0.9 VA 50/60 Hz (at 20°C)
- Poles Description:
- 3P
- Heat Dissipation:
- 0.6-0.6 W at 50/60 Hz
- Protective Cover:
- with
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- [Ie] Rated Operational Current:
- 25 A (at <60°C) at <= 440 V AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC-1 for power circuit || 25 A (at <60°C) at <= 440 V AC-3e for power circuit
- Inrush Power In W:
- 14-14 W 20°C)
- Fire Resistance:
- 850°C IEC 60695-2-1
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Coil Technology:
- built-in bidirectional peak limiting
- Power Dissipation Per Pole:
- 3.2 W AC-1 || 1.25 W AC-3 || 1.25 W AC-3e
- Environmental Disclosure:
- ENVPEP1609001EN
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Net Weight:
- 0.433 kg
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Compatibility Code:
- LC1D
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Maximum Horse Power Rating:
- 2 hp at 115 V AC 60 Hz for 1 phase motors || 3 hp at 230/240 V AC 60 Hz for 1 phase motors || 7.5 hp at 200/208 V AC 60 Hz for 3 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 3 phase motors || 15 hp at 460/480 V AC 60 Hz for 3 phase motors || 20 h
- Depth:
- 92 mm
- Range:
- TeSys || TeSys Deca
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Signaling Circuit Frequency:
- 25...400 Hz
- [Uc] Control Circuit Voltage:
- 24...60 V AC 50/60 Hz || 24...60 V DC
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Rohs Exemption Information:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Rated Breaking Capacity:
- 450 A at 440 V for power circuit conforming to IEC 60947
- Halogen Content Performance:
- Halogen free plastic parts & cables product
- Average Impedance:
- 2 mOhm - Ith 40 A 50 Hz for power circuit
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 40 A gG at <= 690 V coordination type 2 for power circuit
- Circularity Profile:
- ENVEOLI1609001EN
- Product Or Component Type:
- contactor
- Operating Time:
- 45...55 ms closing || 20...90 ms opening
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Device Short Name:
- LC1D
- Pole Contact Composition:
- 3 NO
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Mounting Support:
- plate || rail
- Width:
- 45 mm
- Inrush Power In Va:
- 15-15 VA 50/60 Hz (at 20°C)
- Contactor Application:
- resistive load || motor control
- Pollution Degree:
- 3