TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 115 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.90 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.83 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Maximum Horse Power Rating:
- 2 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 20 hp at 460/480 V AC 50/60 Hz for 3 phase m
- Width:
- 45 mm
- Height:
- 99 mm
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Contactor Application:
- motor control || resistive load
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Rated Breaking Capacity:
- 550 A at 440 V for power circuit conforming to IEC 60947
- Pvc Free:
- Yes
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
- Environmental Disclosure:
- ENVPEP110229EN
- Connections - Terminals:
- control circuit: spring terminals 1 2.5-2.5 mm² - cable stiffness: flexible without cable end || control circuit: spring terminals 2 2.5-2.5 mm² - cable stiffness: flexible without cable end || power circuit: spring terminals 1 4-4 mm² - cable sti
- Operating Time:
- 12...22 ms closing || 4...19 ms opening
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Mounting Support:
- plate || rail
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Inrush Power In Va:
- 70-70 VA 60 Hz cos phi 0.75 (at 20°C) || 70-70 VA 50 Hz cos phi 0.75 (at 20°C)
- Standards:
- CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
- Poles Description:
- 3P
- Pollution Degree:
- 3
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Coil Technology:
- without built-in suppressor module
- Eu Rohs Directive:
- Compliant
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Rohs Exemption Information:
- Yes
- Overvoltage Category:
- III
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Depth:
- 92 mm
- Hold-In Power Consumption In Va:
- 7.5-7.5 VA 60 Hz cos phi 0.3 (at 20°C) || 7-7 VA 50 Hz cos phi 0.3 (at 20°C)
- Tightening Torque:
- control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw clamp terminals pozidriv No 2
- Device Short Name:
- LC1D
- [Icw] Rated Short-Time Withstand Current:
- 260 A 40°C - 10 s for power circuit || 430 A 40°C - 1 s for power circuit || 60 A 40°C - 10 min for power circuit || 138 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Product Certifications:
- LROS (Lloyds register of shipping) || CSA || BV || DNV || UL || RINA || GL || GOST || CCC || UKCA
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Fire Resistance:
- 850°C IEC 60695-2-1
- Circularity Profile:
- ENVEOLI110229EN
- Heat Dissipation:
- 2-3 W at 50/60 Hz
- Power Dissipation Per Pole:
- 2 W AC-3 || 5 W AC-1 || 2 W AC-3e
- Motor Power Kw:
- 7.5 kW at 220...230 V AC 50/60 Hz (AC-3) || 15 kW at 380...400 V AC 50/60 Hz (AC-3) || 15 kW at 415...440 V AC 50/60 Hz (AC-3) || 18.5 kW at 500 V AC 50/60 Hz (AC-3) || 18.5 kW at 660...690 V AC 50/60 Hz (AC-3) || 7.5 kW at 400 V AC 50/60 Hz (AC-4) |
- Warranty:
- 18 months
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Uc] Control Circuit Voltage:
- 115 V AC 50/60 Hz
- Weight:
- 0.375 kg
- Average Impedance:
- 2 mOhm - Ith 50 A 50 Hz for power circuit
- Sustainable Offer Status:
- Green Premium product