Schneider Electric

Schneider Electric LC1D32EHE IEC contactor, TeSys Deca Green, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D32EHE
MPN:
LC1D32EHE
Condition:
New
Warranty:
18 months
Power Dissipation Per Pole:
2 W AC-3 || 5 W AC-1 || 2 W AC-3e
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Protective Cover:
with
Operating Altitude:
0...9842.52 ft (0...3000 m)
Device Short Name:
LC1D
Halogen Content Performance:
Halogen free plastic parts & cables product
Mounting Support:
plate || rail
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Utilisation Category:
AC-1 || AC-3 || AC-3e
Mechanical Durability:
15 Mcycles
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power
Minimum Switching Current:
5 mA for Signaling circuit
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating:
2 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 20 hp at 460/480 V AC 50/60 Hz for 3 phase m
Fire Resistance:
850°C IEC 60695-2-1
Maximum Operating Rate:
3600 cyc/h 60°C
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Poles Description:
3P
[Ie] Rated Operational Current:
32 A (at <60°C) at <= 440 V AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC-1 for power circuit || 32 A (at <60°C) at <= 440 V AC-3e for power circuit
Eu Rohs Directive:
Compliant with Exemptions
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 60 A 40°C - 10 min for power circuit || 138 A 40°C - 1 min for power circuit || 260 A 40°C - 10 s for power circuit || 430 A 40°C - 1
Minimum Switching Voltage:
17 V for Signaling circuit
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Coil Technology:
built-in bidirectional peak limiting
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Hold-In Power Consumption In Va:
1.3-1.3 VA 50/60 Hz (at 20°C)
Country of Origin:
France
Inrush Power In W:
24-24 W 20°C)
Signaling Circuit Frequency:
25...400 Hz
Mercury Free:
Yes
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption In W:
0.8-0.8 W 20°C
Contactor Application:
motor control || resistive load
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Circularity Profile:
ENVEOLI1609001EN
Width:
45 mm
Depth:
92 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Rated Breaking Capacity:
550 A at 440 V for power circuit conforming to IEC 60947
Product Or Component Type:
contactor
$86.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.97 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.