Schneider Electric

Schneider Electric LC1D32KUE IEC contactor, TeSys Deca, nonreversing, 32A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil, open

(No reviews yet) Write a Review
SKU:
LC1D32KUE
MPN:
LC1D32KUE
Condition:
New
Pole Contact Composition:
3 NO
Maximum Horse Power Rating:
2 hp at 115 V AC 50/60 Hz for 1 phase motors || 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 20 hp at 460/480 V AC 50/60 Hz for 3 phase m
Insulation Resistance:
> 10 MOhm for Signaling circuit
Halogen Content Performance:
Halogen free plastic parts & cables product
Device Short Name:
LC1D
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Width:
45 mm
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
Signaling Circuit Frequency:
25...400 Hz
Protective Cover:
with
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Range:
TeSys || TeSys Deca
Coil Technology:
built-in bidirectional peak limiting
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
Poles Description:
3P
Depth:
92 mm
Mechanical Durability:
15 Mcycles
Maximum Operating Rate:
3600 cyc/h 60°C
Contactor Application:
resistive load || motor control
Eu Rohs Directive:
Compliant with Exemptions
Ip Degree Of Protection:
IP20 front face IEC 60529
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Inrush Power In W:
18-18 W 20°C)
Flame Retardance:
V1 conforming to UL 94
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Uc] Control Circuit Voltage:
100...250 V AC 50/60 Hz || 100...250 V DC
Motor Power Kw:
7.5 kW at 220...230 V AC 50 Hz (AC-3) || 15 kW at 380...400 V AC 50 Hz (AC-3) || 15 kW at 415 V AC 50 Hz (AC-3) || 15 kW at 440 V AC 50 Hz (AC-3) || 18.5 kW at 500 V AC 50 Hz (AC-3) || 18.5 kW at 660...690 V AC 50 Hz (AC-3) || 7.5 kW at 220...230 V A
Pollution Degree:
3
Product Or Component Type:
contactor
Hold-In Power Consumption In W:
1.1-1.1 W 20°C
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Sustainable Offer Status:
Green Premium product
Auxiliary Contact Composition:
1 NO + 1 NC
Range Of Product:
TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Inrush Power In Va:
25-25 VA 50/60 Hz (at 20°C)
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Circularity Profile:
ENVEOLI1609001EN
Utilisation Category:
AC-3 || AC-1 || AC-3e
Mercury Free:
Yes
Rated Breaking Capacity:
550 A at 440 V for power circuit conforming to IEC 60947
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Heat Dissipation:
1.1-1.1 W at 50/60 Hz
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Rohs Exemption Information:
Yes
$76.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 32A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.97 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose