Schneider Electric LC1D386BL IEC contactor, TeSys Deca, nonreversing, 38A, 20HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption, 24VDC coil, open

(No reviews yet) Write a Review
SKU:
LC1D386BL
MPN:
LC1D386BL
Condition:
New
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Product Or Component Type:
contactor
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Breaking Capacity:
550 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating:
10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 5 hp at 240 V AC 50/60 Hz for 1 phase motors || 20 hp at 480 V AC 50/60 Hz for 3 phase motors || 25 hp at 600 V AC 50/60 Hz for 3 phase motors
Maximum Operating Rate:
3600 cyc/h 60°C
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pole Contact Composition:
3 NO
Pollution Degree:
3
Hold-In Power Consumption In W:
2.4-2.4 W 20°C
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Standards:
CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 || IEC 60335-1
Insulation Resistance:
> 10 MOhm for Signaling circuit
[Icw] Rated Short-Time Withstand Current:
60 A 40°C - 10 min for power circuit || 430 A 40°C - 1 s for power circuit || 150 A 40°C - 1 min for power circuit || 310 A 40°C - 10 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Eu Rohs Directive:
Compliant with Exemptions
Auxiliary Contact Composition:
1 NO + 1 NC
Device Short Name:
LC1D
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Compatibility Code:
LC1D
Minimum Switching Current:
5 mA for Signaling circuit
Range Of Product:
TeSys Deca
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Protective Treatment:
THIEC 60068-2-30
Rohs Exemption Information:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Control Circuit Type:
DC low consumption
Flame Retardance:
V1 conforming to UL 94
Mounting Support:
rail || plate
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Minimum Switching Voltage:
17 V for Signaling circuit
Electrical Durability:
1.4 Mcycles 50 A AC-1 <= 440 V || 1.4 Mcycles 38 A AC-3 <= 440 V || 1.4 Mcycles 38 A AC-3e <= 440 V
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.8...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Operating Altitude:
0...9842.52 ft (0...3000 m)
Fire Resistance:
850°C IEC 60695-2-1
Contactor Application:
motor control || resistive load
Connections - Terminals:
control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 10 mm
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 2.5 N.m lugs-ring terminals flat Ø 8 mm M4 || power circuit 2.5 N.m lugs-ring terminals Philips No 2 M4 |
Mechanical Durability:
30 Mcycles
$289.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 38A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 25HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.98 inches deep. It weighs 1.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.