Schneider Electric

Schneider Electric LC1D38EHE IEC contactor, TeSys Deca Green, nonreversing, 38A, 20HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48/130VAC/VDC coil

(No reviews yet) Write a Review
SKU:
LC1D38EHE
MPN:
LC1D38EHE
Condition:
New
Contactor Application:
resistive load || motor control
Rated Breaking Capacity:
550 A at 440 V for power circuit conforming to IEC 60947
Mechanical Durability:
15 Mcycles
Product Certifications:
CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
Circularity Profile:
ENVEOLI1609001EN
Inrush Power In W:
24-24 W 20°C)
Compatibility Code:
LC1D
Inrush Power In Va:
25-25 VA 50/60 Hz (at 20°C)
Utilisation Category:
AC-3 || AC-1 || AC-3e
Ip Degree Of Protection:
IP20 front face IEC 60529
Minimum Switching Current:
5 mA for Signaling circuit
Signaling Circuit Frequency:
25...400 Hz
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Protective Cover:
with
Hold-In Power Consumption In W:
0.8-0.8 W 20°C
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 50 A (at 60°C) for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Environmental Disclosure:
ENVPEP1609001EN
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 63 A gG at <= 690 V coordination type 1 for power circuit || 63 A gG at <= 690 V coordination type 2 for power circuit
Product Or Component Type:
contactor
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Motor Power Kw:
9 kW at 220...230 V AC 50 Hz (AC-3) || 18.5 kW at 380...400 V AC 50 Hz (AC-3) || 18.5 kW at 415 V AC 50 Hz (AC-3) || 18.5 kW at 440 V AC 50 Hz (AC-3) || 18.5 kW at 500 V AC 50 Hz (AC-3) || 18.5 kW at 660...690 V AC 50 Hz (AC-3) || 9 kW at 220...230 V
Poles Description:
3P
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Fire Resistance:
850°C IEC 60695-2-1
Insulation Resistance:
> 10 MOhm for Signaling circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 2.5 N.m screw clamp terminals flat Ø 6 mm || power circuit 2.5 N.m screw clamp terminals Philips No 2 || power
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 550 A at 440 V for power circuit conforming to IEC 60947
Device Short Name:
LC1D
Pole Contact Composition:
3 NO
Minimum Switching Voltage:
17 V for Signaling circuit
Heat Dissipation:
0.8-0.8 W at 50/60 Hz
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Maximum Horse Power Rating:
2 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 20 hp at 460/480 V AC 60 Hz for 3 phase motors || 25 hp
Range:
TeSys || TeSys Deca
Eu Rohs Directive:
Compliant with Exemptions
Halogen Content Performance:
Halogen free plastic parts & cables product
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 8 Gn for 11 ms)
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Operating Time:
45...55 ms closing || 20...90 ms opening
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Mounting Support:
plate || rail
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
Standards:
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
Average Impedance:
2 mOhm - Ith 50 A 50 Hz for power circuit
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
$100.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 38A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 7.5HP at 200 to 208VAC, 10HP at 240VAC, 20HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 2HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 80A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.97 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose