Schneider Electric

Schneider Electric LC1D40A3BD IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A3BD
MPN:
LC1D40A3BD
Condition:
New
Net Weight:
0.925 kg
Insulation Resistance:
> 10 MOhm for Signaling circuit
Height:
122 mm
Flame Retardance:
V1 conforming to UL 94
Sustainable Packaging:
Yes
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Pole Contact Composition:
3 NO
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Overvoltage Category:
III
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Ip Degree Of Protection:
IP20 front face IEC 60529
Signaling Circuit Frequency:
25...400 Hz
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Protective Treatment:
THIEC 60068-2-30
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Compatibility Code:
LC1D
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Time Constant:
34 ms
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.
Mounting Support:
plate || rail
Inrush Power In W:
19-19 W 20°C)
Product Or Component Type:
contactor
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Poles Description:
3P
Contactor Application:
motor control || resistive load
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Mechanical Durability:
10 Mcycles
Sustainable Offer Status:
Green Premium product
Auxiliary Contact Composition:
1 NO + 1 NC
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Eu Rohs Directive:
Compliant
Maximum Horse Power Rating:
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
Range Of Product:
TeSys Deca
Environmental Disclosure:
ENVPEP1503009EN
Minimum Switching Voltage:
17 V for Signaling circuit
Operating Time:
50±15 % ms closing || 20±20 % ms opening
Tightening Torque:
power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connectors 0.75-25 mm² hexagonal 4 mm || control circuit 1.7 N.m screw clamp terminals pozidriv No 2 || power circuit 2.5 N.m screw
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Range:
TeSys || TeSys Deca
Warranty:
18 months
Circularity Profile:
ENVEOLI1503009EN
Depth:
120 mm
$275.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.04 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose