Schneider Electric

Schneider Electric LC1D40A6EHE IEC contactor, TeSys Deca Green, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 48/130VAC/VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A6EHE
MPN:
LC1D40A6EHE
Condition:
New
Control Circuit Type:
AC/DC 50/60 Hz AC/DC electronic
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree:
3
Inrush Power In W:
19-19 W 20°C)
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Associated Fuse Rating:
80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947-5-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Overvoltage Category:
III
Heat Dissipation:
0.9-0.9 W at 50/60 Hz
Width:
55 mm
Warranty:
18 months
Device Short Name:
LC1D
Flame Retardance:
V1 conforming to UL 94
Pole Contact Composition:
3 NO
Weight:
0.992 kg
Net Weight:
0.992 kg
Tightening Torque:
control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
Height:
122 mm
[Uc] Control Circuit Voltage:
48...130 V AC 50/60 Hz || 48...130 V DC
Poles Description:
3P
Minimum Switching Voltage:
17 V for Signaling circuit
Electrical Durability:
2 Mcycles 35 A AC-3 <= 440 V || 0.7 Mcycles 60 A AC-1 <= 440 V || 2 Mcycles 35 A AC-3e <= 440 V
Hold-In Power Consumption In Va:
1.4-1.4 VA 50/60 Hz (at 20°C)
Minimum Switching Current:
5 mA for Signaling circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Rohs Exemption Information:
Yes
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Utilisation Category:
AC-3 || AC-1 || AC-3e
Environmental Disclosure:
ENVPEP1607010EN
Mounting Support:
plate || rail
Control Circuit Voltage Limits:
<= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
Depth:
120 mm
Connections - Terminals:
power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
Signaling Circuit Frequency:
25...400 Hz
Compatibility Code:
LC1D
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Country of Origin:
France
Auxiliary Contact Composition:
1 NO + 1 NC
Product Or Component Type:
contactor
Sustainable Offer Status:
Green Premium product
Hold-In Power Consumption In W:
0.9-0.9 W 20°C
[Icw] Rated Short-Time Withstand Current:
72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Fire Resistance:
850°C IEC 60695-2-1
Maximum Operating Rate:
3600 cyc/h 60°C
Protective Cover:
with
Range:
TeSys || TeSys Deca
$330.00

Description

TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.19 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose