Schneider Electric

Schneider Electric LC1D40A6FD IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 110VDC coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A6FD
MPN:
LC1D40A6FD
Condition:
New
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Poles Description:
3P
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Mercury Free:
Yes
Auxiliary Contact Composition:
1 NO + 1 NC
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Range:
TeSys || TeSys Deca
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Mounting Support:
plate || rail
Signaling Circuit Frequency:
25...400 Hz
[Uc] Control Circuit Voltage:
110 V DC
Control Circuit Voltage Limits:
0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
Average Impedance:
1.5 mOhm - Ith 60 A 50 Hz for power circuit
Operating Altitude:
0...9842.52 ft (0...3000 m)
Overvoltage Category:
III
Range Of Product:
TeSys Deca
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Operating Time:
50±15 % ms closing || 20±20 % ms opening
Protective Cover:
with
Protective Treatment:
THIEC 60068-2-30
Net Weight:
0.925 kg
Warranty:
18 months
Contactor Application:
motor control || resistive load
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Mechanical Durability:
10 Mcycles
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Pole Contact Composition:
3 NO
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Compatibility Code:
LC1D
Eu Rohs Directive:
Compliant
Electrical Durability:
0.7 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Control Circuit Type:
DC standard
Sustainable Packaging:
Yes
Fire Resistance:
850°C IEC 60695-2-1
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Product Or Component Type:
contactor
Associated Fuse Rating:
10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Maximum Operating Rate:
3600 cyc/h 60°C
Country of Origin:
France
Weight:
0.925 kg
$275.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 110 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.04 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose