Schneider Electric LC1D40A6GD IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 125VDC coil, open style
Schneider Electric
$275.00
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 125 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.04 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- [Icw] Rated Short-Time Withstand Current:
- 320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- [Uc] Control Circuit Voltage:
- 125 V DC
- Electrical Durability:
- 0.7 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
- Fire Resistance:
- 850°C IEC 60695-2-1
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Control Circuit Type:
- DC standard
- Utilisation Category:
- AC-4 || AC-1 || AC-3 || AC-3e
- Reach Free Of Svhc:
- Yes
- Pvc Free:
- Yes
- Coil Technology:
- built-in bidirectional peak limiting diode suppressor
- Protective Cover:
- with
- Standards:
- EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
- Contactor Application:
- resistive load || motor control
- Net Weight:
- 0.925 kg
- Inrush Power In W:
- 19-19 W 20°C)
- Width:
- 55 mm
- Time Constant:
- 34 ms
- [Ui] Rated Insulation Voltage:
- power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
- Power Dissipation Per Pole:
- 2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
- [Ie] Rated Operational Current:
- 60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Rated Breaking Capacity:
- 800 A at 440 V for power circuit conforming to IEC 60947
- Range:
- TeSys || TeSys Deca
- Pollution Degree:
- 3
- Eu Rohs Directive:
- Compliant
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
- Maximum Horse Power Rating:
- 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Mechanical Durability:
- 10 Mcycles
- Operating Time:
- 50±15 % ms closing || 20±20 % ms opening
- Motor Power Kw:
- 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.
- Circularity Profile:
- ENVEOLI1503009EN
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Weight:
- 0.925 kg
- Product Or Component Type:
- contactor
- Sustainable Packaging:
- Yes
- Average Impedance:
- 1.5 mOhm - Ith 60 A 50 Hz for power circuit
- Device Short Name:
- LC1D
- Protective Treatment:
- THIEC 60068-2-30
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Connections - Terminals:
- control circuit: lugs-ring terminals - external diameter: 8 mm || power circuit: lugs-ring terminals - external diameter: 16.5 mm
- Control Circuit Voltage Limits:
- 0.1...0.3 Uc -40-70°C drop-out DC || 0.75...1.25 Uc -40-60°C operational DC || 1...1.25 Uc 60-70°C operational DC
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Environmental Disclosure:
- ENVPEP1503009EN
- [Ith] Conventional Free Air Thermal Current:
- 10 A (at 60°C) for Signaling circuit || 60 A (at 60°C) for power circuit
- Range Of Product:
- TeSys Deca