Schneider Electric

Schneider Electric LC1D40A6P7 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, 3 phase, 3 pole, 3 NO, 230VAC 50/60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40A6P7
MPN:
LC1D40A6P7
Condition:
New
Warranty:
18 months
Minimum Switching Voltage:
17 V for Signaling circuit
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Utilisation Category:
AC-4 || AC-1 || AC-3 || AC-3e
Environmental Disclosure:
ENVPEP1503009EN
Control Circuit Type:
AC 50/60 Hz
Insulation Resistance:
> 10 MOhm for Signaling circuit
Protective Treatment:
THIEC 60068-2-30
Inrush Power In Va:
140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
Range:
TeSys || TeSys Deca
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Ip Degree Of Protection:
IP20 front face IEC 60529
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
[Uc] Control Circuit Voltage:
230 V AC 50/60 Hz
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Heat Dissipation:
4-5 W at 50/60 Hz
Flame Retardance:
V1 conforming to UL 94
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Country of Origin:
Indonesia
Mounting Support:
rail || plate
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating:
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
Device Short Name:
LC1D
Operating Time:
4...19 ms opening || 12...26 ms closing
Signaling Circuit Frequency:
25...400 Hz
Net Weight:
0.85 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Mechanical Durability:
6 Mcycles
Eu Rohs Directive:
Compliant
Sustainable Offer Status:
Green Premium product
Fire Resistance:
850°C IEC 60695-2-1
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Auxiliary Contact Composition:
1 NO + 1 NC
Maximum Operating Rate:
3600 cyc/h 60°C
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL || power circuit 690 V IEC 60947-4-1
Rohs Exemption Information:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Coil Technology:
without built-in suppressor module
Compatibility Code:
LC1D
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
$327.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. Contactor is supplied with a 230 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose