Schneider Electric

Schneider Electric LC1D40AR7 IEC contactor, TeSys Deca, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 440VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D40AR7
MPN:
LC1D40AR7
Condition:
New
Contactor Application:
motor control || resistive load
Signaling Circuit Frequency:
25...400 Hz
Auxiliary Contact Composition:
1 NO + 1 NC
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Operating Altitude:
0...9842.52 ft (0...3000 m)
Protective Cover:
with
Eu Rohs Directive:
Compliant
Maximum Horse Power Rating:
5 hp at 230/240 V AC 50/60 Hz for 1 phase motors || 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 30 hp at 575/600 V AC 50/60 Hz for 3 phase motors || 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 3 hp at 115 V AC 50/60 Hz for 1 phase m
Electrical Durability:
1.4 Mcycles 60 A AC-1 <= 440 V || 1.5 Mcycles 40 A AC-3 <= 440 V || 1.5 Mcycles 40 A AC-3e <= 440 V
Maximum Operating Rate:
3600 cyc/h 60°C
Irms Rated Making Capacity:
140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Power Dissipation Per Pole:
2.4 W AC-3 || 5.4 W AC-1 || 2.4 W AC-3e
Protective Treatment:
THIEC 60068-2-30
Country of Origin:
France
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Operating Time:
4...19 ms opening || 12...26 ms closing
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Device Short Name:
LC1D
Minimum Switching Voltage:
17 V for Signaling circuit
Mechanical Durability:
6 Mcycles
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Heat Dissipation:
4-5 W at 50/60 Hz
Compatibility Code:
LC1D
Insulation Resistance:
> 10 MOhm for Signaling circuit
Weight:
0.85 kg
Motor Power Kw:
18.5 kW at 380...400 V AC 50/60 Hz (AC-3) || 11 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 415...440 V AC 50/60 Hz (AC-3) || 22 kW at 500 V AC 50/60 Hz (AC-3) || 30 kW at 660...690 V AC 50/60 Hz (AC-3) || 9 kW at 400 V AC 50/60 Hz (AC-4) || 18.
Range Of Product:
TeSys Deca
Poles Description:
3P
Pole Contact Composition:
3 NO
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
[Icw] Rated Short-Time Withstand Current:
320 A 40°C - 10 s for power circuit || 720 A 40°C - 1 s for power circuit || 72 A 40°C - 10 min for power circuit || 165 A 40°C - 1 min for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
Product Certifications:
CCC || UL || CB Scheme || CSA || CE || UKCA || Marine || EAC
Warranty:
18 months
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Circularity Profile:
ENVEOLI1503009EN
Toxic Heavy Metal Free:
Yes
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Fire Resistance:
850°C IEC 60695-2-1
Rohs Exemption Information:
Yes
Depth:
120 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Minimum Switching Current:
5 mA for Signaling circuit
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Overvoltage Category:
III
$261.60

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 440 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
View AllClose