Schneider Electric

Schneider Electric LC1D40F7 IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 110VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D40F7
MPN:
LC1D40F7
Condition:
New
Protective Cover:
with
Range:
TeSys
Depth:
119 mm
Sustainable Offer Status:
Green Premium product
Range Of Product:
TeSys Deca
Minimum Switching Current:
5 mA for control circuit
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Eu Rohs Directive:
Compliant
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Country of Origin:
France
Height:
127 mm
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Insulation Resistance:
> 10 MOhm for control circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Mounting Support:
rail || plate
Mechanical Durability:
6000000 cycles
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Width:
75 mm
Product Or Component Type:
contactor
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Tightening Torque:
control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2
Pvc Free:
Yes
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Operating Time:
4...19 ms opening || 12...26 ms closing
Flame Retardance:
V1 conforming to UL 94
Reach Free Of Svhc:
Yes
Product Certifications:
DNV || GL || CCC || LROS (Lloyds register of shipping) || RINA || BV || GOST || UL || CSA || CB
Control Circuit Type:
AC 50/60 Hz
Warranty:
18 months
Net Weight:
1.4 kg
Maximum Operating Rate:
3600 cyc/h 60°C
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Environmental Disclosure:
ENVPEP110205EN
Climatic Withstand:
IACS E10 exposure to damp heat
Motor Power Kw:
18.5 kW at 380...400 V AC 50 Hz (AC-3) || 22 kW at 500 V AC 50 Hz (AC-3) || 30 kW at 660...690 V AC 50 Hz (AC-3) || 22 kW at 1000 V AC 50 Hz (AC-3) || 22 kW at 415 V AC 50 Hz (AC-3) || 22 kW at 440 V AC 50 Hz (AC-3) || 11 kW at 220...230 V AC 50 Hz (
Minimum Switching Voltage:
17 V for control circuit
Standards:
EN 60947-5-1 || IEC 60947-5-1 || EN 60947-4-1 || UL 508 || IEC 60947-4-1 || CSA C22.2 No 14
Toxic Heavy Metal Free:
Yes
Operating Altitude:
0...9842.52 ft (0...3000 m)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Poles Description:
3P
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile:
N/A
$361.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 110 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.