Schneider Electric

Schneider Electric LC1D40L6 IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 208VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D40L6
MPN:
LC1D40L6
Condition:
New
Operating Altitude:
9842.52 ft (3000 m) without derating
Operating Time:
12...26 ms closing || 4...19 ms opening
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Fire Resistance:
850°C IEC 60695-2-1
Maximum Horse Power Rating:
10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 200/208 V AC 60 Hz for 3 phase motors conforming to UL || 10 hp at 230/240 V AC 60 Hz for 3 phase motors conforming to CSA || 10 hp at 230/240 V AC 60 Hz for 3 phase motors
Pvc Free:
Yes
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Mechanical Durability:
6000000 cycles
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Standards:
IEC 60947-5-1 || EN 60947-5-1 || EN 60947-4-1 || IEC 60947-4-1 || CSA C22.2 No 14 || UL 508
Range:
TeSys
Reach Free Of Svhc:
Yes
Tightening Torque:
control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw clamp terminal flat Ø 6 mm || power circuit 5 N.m screw clamp terminal flat Ø 8 mm || control circui
Connections - Terminals:
control circuit: screw clamp terminal 1 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 2 1-4 mm² - cable stiffness: solid without cable end || control circuit: screw clamp terminal 1 1-2.5 mm² - cable s
Insulation Resistance:
> 10 MOhm for control circuit
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Device Short Name:
LC1D
Utilisation Category:
AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
Poles Description:
3P
Contactor Application:
motor control || resistive load
Sustainable Offer Status:
Green Premium product
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Flame Retardance:
V1 conforming to UL 94
Irms Rated Making Capacity:
140 A AC for control circuit conforming to IEC 60947-5-1 || 800 A at 440 V for power circuit conforming to IEC 60947
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Toxic Heavy Metal Free:
Yes
Minimum Switching Voltage:
17 V for control circuit
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Minimum Switching Current:
5 mA for control circuit
[Uc] Control Circuit Voltage:
200 V AC 60 Hz
Weight:
1.4 kg
Pole Contact Composition:
3 NO
Overvoltage Category:
III
Permissible Ambient Air Temperature Around The Device:
-5-60°C || -40-70°C at Uc
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Range Of Product:
TeSys Deca
Country of Origin:
United States
Net Weight:
1.4 kg
Control Circuit Voltage Limits:
0.85...1.1 Uc 60-60°C operational AC 60 Hz || 0.3...0.6 Uc 60-60°C drop-out AC 60 Hz
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Eu Rohs Directive:
Compliant
Product Certifications:
CSA || UL || GOST || RINA || BV || DNV || GL || LROS (Lloyds register of shipping) || CCC || UKCA
Compatibility Code:
LC1D
[Ie] Rated Operational Current:
60 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 40 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Circularity Profile:
N/A
$541.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 208 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.