Schneider Electric LC1D40U7 IEC contactor, TeSys D, nonreversing, 40A, 30HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D40U7
MPN:
LC1D40U7
Condition:
New
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Reach Free Of Svhc:
Yes
Associated Fuse Rating:
10 A gG for control circuit conforming to IEC 60947-5-1 || 80 A gG at <= 690 V coordination type 1 for power circuit || 80 A gG at <= 690 V coordination type 2 for power circuit
Control Circuit Type:
AC 50/60 Hz
Net Weight:
1.4 kg
Minimum Switching Current:
5 mA for control circuit
Motor Power Kw:
18.5 kW at 380...400 V AC 50 Hz (AC-3) || 22 kW at 500 V AC 50 Hz (AC-3) || 30 kW at 660...690 V AC 50 Hz (AC-3) || 22 kW at 1000 V AC 50 Hz (AC-3) || 22 kW at 415 V AC 50 Hz (AC-3) || 22 kW at 440 V AC 50 Hz (AC-3) || 11 kW at 220...230 V AC 50 Hz (
Maximum Horse Power Rating:
3 hp at 115 V AC 60 Hz for 1 phase motors || 5 hp at 230/240 V AC 60 Hz for 1 phase motors || 10 hp at 200/208 V AC 60 Hz for 3 phase motors || 10 hp at 230/240 V AC 60 Hz for 3 phase motors || 30 hp at 460/480 V AC 60 Hz for 3 phase motors || 30 hp
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Compatibility Code:
LC1D
[Ui] Rated Insulation Voltage:
control circuit 600 V CSA || control circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1
Height:
127 mm
Irms Rated Making Capacity:
800 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
Mechanical Robustness:
shocks contactor opened 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz)
Standards:
IEC 60947-5-1 || IEC 60947-4-1 || UL 508 || EN 60947-4-1 || EN 60947-5-1 || CSA C22.2 No 14
Operating Time:
4...19 ms opening || 12...26 ms closing
Product Or Component Type:
contactor
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Poles Description:
3P
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
Mechanical Durability:
6000000 cycles
Weight:
1.4 kg
Pole Contact Composition:
3 NO
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Insulation Resistance:
> 10 MOhm for control circuit
Mounting Support:
rail || plate
Device Short Name:
LC1D
Protective Cover:
with
Range:
TeSys
Power Dissipation Per Pole:
5.4 W AC-1 || 2.4 W AC-3 || 2.4 W AC-3e
Rated Breaking Capacity:
800 A at 440 V for power circuit conforming to IEC 60947
Circularity Profile:
N/A
Width:
75 mm
Eu Rohs Directive:
Compliant
Fire Resistance:
850°C IEC 60695-2-1
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947
Maximum Operating Rate:
3600 cyc/h 60°C
Utilisation Category:
AC-4 || AC-1 || AC-2 || AC-3 || AC-3e
Auxiliary Contact Composition:
1 NO + 1 NC
Mercury Free:
Yes
Climatic Withstand:
IACS E10 exposure to damp heat
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Depth:
119 mm
Environmental Disclosure:
ENVPEP110205EN
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for control circuit || 60 A (at 60°C) for power circuit
Minimum Switching Voltage:
17 V for control circuit
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
$361.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 40A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 10HP at 200 to 208VAC, 10HP at 240VAC, 30HP at 480VAC and 30HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 90A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 240 VAC50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.