Schneider Electric LC1D50A6EHE IEC contactor, TeSys Deca Green, nonreversing, 50A, 40HP at 480VAC, 3 phase, 3 pole, 3 NO, 48/130VAC/VDC coil, open style
Schneider Electric
$367.20
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. Equipped with an electronic coil, wide band voltage 48-130V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 2.20 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Poles Description:
- 3P
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- Overvoltage Category:
- III
- Pollution Degree:
- 3
- Connections - Terminals:
- power circuit: lugs-ring terminals - external diameter: 16.5 mm || control circuit: lugs-ring terminals - external diameter: 8 mm
- Compatibility Code:
- LC1D
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Control Circuit Voltage Limits:
- <= 0.1 Uc -40-70°C drop-out AC/DC || 0.85...1.1 Uc -40-60°C operational AC/DC || 1...1.1 Uc 60-70°C operational AC/DC
- Product Or Component Type:
- contactor
- Rated Breaking Capacity:
- 900 A at 440 V for power circuit conforming to IEC 60947
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Country of Origin:
- France
- Circularity Profile:
- ENVEOLI1607010EN
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Mechanical Durability:
- 6 Mcycles
- Environmental Disclosure:
- ENVPEP1607010EN
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Height:
- 122 mm
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Operating Time:
- 55...65 ms closing || 20...80 ms opening
- Mounting Support:
- rail || plate
- Pole Contact Composition:
- 3 NO
- [Ue] Rated Operational Voltage:
- power circuit <= 690 V AC 25...400 Hz
- Range:
- TeSys || TeSys Deca
- Inrush Power In Va:
- 23-23 VA 50/60 Hz (at 20°C)
- Protective Cover:
- with
- Maximum Horse Power Rating:
- 3 hp at 115 V AC 60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors || 15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 h
- [Uc] Control Circuit Voltage:
- 48...130 V AC 50/60 Hz || 48...130 V DC
- Motor Power Kw:
- 15 kW at 220...230 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3) || 30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 H
- Electrical Durability:
- 1.8 Mcycles 42 A AC-3 <= 440 V || 0.5 Mcycles 80 A AC-1 <= 440 V || 1.8 Mcycles 42 A AC-3e <= 440 V
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Hold-In Power Consumption In W:
- 0.9-0.9 W 20°C
- Fire Resistance:
- 850°C IEC 60695-2-1
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC-3e for power circuit
- Warranty:
- 18 months
- Tightening Torque:
- control circuit 1.7 N.m lugs-ring terminals flat Ø 6 mm M3.5 || control circuit 1.7 N.m lugs-ring terminals Philips No 2 M3.5 || power circuit 6 N.m lugs-ring terminals hexagonal 10 mm M6 || power circuit 6 N.m lugs-ring terminals pozidriv No 2 M4 |
- [Icw] Rated Short-Time Withstand Current:
- 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms f
- Width:
- 55 mm
- Signaling Circuit Frequency:
- 25...400 Hz
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Net Weight:
- 0.997 kg
- Hold-In Power Consumption In Va:
- 1.4-1.4 VA 50/60 Hz (at 20°C)
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Weight:
- 0.997 kg