Schneider Electric

Schneider Electric LC1D50AB6 IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VAC 60Hz coil, open style

(No reviews yet) Write a Review
SKU:
LC1D50AB6
MPN:
LC1D50AB6
Condition:
New
[Ie] Rated Operational Current:
80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Toxic Heavy Metal Free:
Yes
Compatibility Code:
LP1D
Flame Retardance:
V1 conforming to UL 94
Control Circuit Type:
AC 60 Hz
Hold-In Power Consumption In Va:
13-13 VA 60 Hz cos phi 0.3 (at 20°C)
Tightening Torque:
control circuit 1.7 N.m screw clamps terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamps terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || control circuit 5 N.m EverLink BTR screw conn
Mechanical Durability:
6 Mcycles
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1503009EN
Poles Description:
3P
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Circularity Profile:
ENVEOLI1503009EN
Eu Rohs Directive:
Compliant
[Icw] Rated Short-Time Withstand Current:
100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1 s for power circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 m
Pvc Free:
Yes
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
[Ui] Rated Insulation Voltage:
power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA || power circuit 600 V UL || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 600 V CSA || Signaling circuit 600 V UL
Maximum Horse Power Rating:
3 hp at 115 V AC 50/60 Hz for 1 phase motors || 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 15 hp at 200/208 V AC 50/60 Hz for 3 phase motors || 15 hp at 230/240 V AC 50/60 Hz for 3 phase motors || 40 hp at 460/480 V AC 50/60 Hz for 3 phase
Sustainable Packaging:
Yes
Connections - Terminals:
control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Pole Contact Composition:
3 NO
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Electrical Durability:
1.45 Mcycles 50 A AC-3 <= 440 V || 1.1 Mcycles 80 A AC-1 <= 440 V
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Insulation Resistance:
> 10 MOhm for Signaling circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Contactor Application:
resistive load || motor control
Product Or Component Type:
contactor
Auxiliary Contact Composition:
1 NO + 1 NC
Maximum Operating Rate:
3600 cyc/h 60°C
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Ip Degree Of Protection:
IP20 front face IEC 60529
Mercury Free:
Yes
Country of Origin:
United States
Fire Resistance:
850°C IEC 60695-2-1
Minimum Switching Current:
5 mA for Signaling circuit
Mounting Support:
plate || rail
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Control Circuit Voltage Limits:
0.3...0.6 Uc -40-70°C drop-out AC 60 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 60 Hz
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
Standards:
EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || CSA C22.2 No 14 || UL 60947-4-1 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ || IEC 60335-1:Clause 30.2
Operating Altitude:
0...9842.52 ft (0...3000 m)
Depth:
120 mm
$295.20

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.