Pole Contact Composition:
3 NO
Connections - Terminals:
control circuit: screw clamp terminals 2 1-2.5 mm² - cable stiffness: flexible with cable end || control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - c
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Contactor Application:
resistive load || motor control
Coil Technology:
built-in bidirectional peak limiting diode suppressor
Poles Description:
3P
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Non-Overlap Time:
1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
Signaling Circuit Frequency:
25...400 Hz
Hold-In Power Consumption In W:
7.4-7.4 W 20°C
Protective Treatment:
THIEC 60068-2-30
Minimum Switching Current:
5 mA for Signaling circuit
Tightening Torque:
control circuit 1.7 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminals Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BTR screw connecto
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Overvoltage Category:
III
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ith] Conventional Free Air Thermal Current:
10 A (at 60°C) for Signaling circuit || 80 A (at 60°C) for power circuit
Operating Time:
50±15 % ms closing || 16...24 ms opening
Protective Cover:
with
Ip Degree Of Protection:
IP20 front face IEC 60529
Device Short Name:
LC1D
Net Weight:
0.93 kg
Sustainable Offer Status:
Green Premium product
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pollution Degree:
3
Fire Resistance:
850°C IEC 60695-2-1
Rated Breaking Capacity:
900 A at 440 V for power circuit conforming to IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Insulation Resistance:
> 10 MOhm for Signaling circuit
Range Of Product:
TeSys Deca
Product Or Component Type:
contactor
Inrush Power In W:
19-19 W 20°C)
Motor Power Kw:
15 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 380...400 V AC 50/60 Hz (AC-3) || 30 kW at 500 V AC 50/60 Hz (AC-3) || 33 kW at 660...690 V AC 50/60 Hz (AC-3) || 25 kW at 415 V AC 50/60 Hz (AC-3) || 30 kW at 440 V AC 50/60 Hz (AC-3) || 11 kW at 4
Mechanical Durability:
10 Mcycles
Permissible Ambient Air Temperature Around The Device:
-40-60°C || 60-70°C with derating
Compatibility Code:
LC1D
Mechanical Robustness:
vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
Pvc Free:
Yes
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz || power circuit <= 300 V DC
Environmental Disclosure:
ENVPEP1503009EN
Mounting Support:
plate || rail
Minimum Switching Voltage:
17 V for Signaling circuit
Range:
TeSys || TeSys Deca
Auxiliary Contact Composition:
1 NO + 1 NC
Control Circuit Type:
DC standard
$306.00

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.