Schneider Electric LC1D50AFC7 IEC contactor, TeSys Deca, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 127VAC 50/60Hz coil, open
Schneider Electric
$295.20
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 127 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Pollution Degree:
- 3
- Fire Resistance:
- 850°C IEC 60695-2-1
- Overvoltage Category:
- III
- [Ie] Rated Operational Current:
- 50 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC AC-3e for power circuit
- Heat Dissipation:
- 4-5 W at 50/60 Hz
- Maximum Operating Rate:
- 3600 cyc/h 60°C
- Inrush Power In Va:
- 140-140 VA 60 Hz cos phi 0.75 (at 20°C) || 160-160 VA 50 Hz cos phi 0.75 (at 20°C)
- Mounting Support:
- plate || rail
- Auxiliary Contact Composition:
- 1 NO + 1 NC
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Hold-In Power Consumption In Va:
- 13-13 VA 60 Hz cos phi 0.3 (at 20°C) || 15-15 VA 50 Hz cos phi 0.3 (at 20°C)
- Device Short Name:
- LC1D
- Operating Time:
- 4...19 ms opening || 12...26 ms closing
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 10 Gn for 11 ms)
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- China Rohs Regulation:
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Motor Power Kw:
- 15 kW at 220...230 V AC 50/60 Hz (AC-3) || 22 kW at 380...400 V AC 50/60 Hz (AC-3) || 30 kW at 500 V AC 50/60 Hz (AC-3) || 33 kW at 660...690 V AC 50/60 Hz (AC-3) || 25 kW at 415 V AC 50/60 Hz (AC-3) || 30 kW at 440 V AC 50/60 Hz (AC-3) || 11 kW at 4
- Control Circuit Voltage Limits:
- 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz
- Power Dissipation Per Pole:
- 3.7 W AC-3 || 9.6 W AC-1 || 3.7 W AC-3e
- Depth:
- 120 mm
- Rohs Exemption Information:
- Yes
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Control Circuit Type:
- AC 50/60 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Permissible Ambient Air Temperature Around The Device:
- -40-60°C || 60-70°C with derating
- Mercury Free:
- Yes
- Sustainable Packaging:
- Yes
- Poles Description:
- 3P
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Sustainable Offer Status:
- Green Premium product
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- Circularity Profile:
- ENVEOLI1503009EN
- Tightening Torque:
- control circuit 1.7 N.m EverLink BTR screw connectors flat Ø 6 mm || control circuit 1.7 N.m EverLink BTR screw connectors Philips No 2 || power circuit 8 N.m EverLink BTR screw connectors 25-35 mm² hexagonal 4 mm || power circuit 5 N.m EverLink BT
- Toxic Heavy Metal Free:
- Yes
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Flame Retardance:
- V1 conforming to UL 94
- Signaling Circuit Frequency:
- 25...400 Hz
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Compatibility Code:
- LC1D
- Range Of Product:
- TeSys Deca
- Irms Rated Making Capacity:
- 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1 || 900 A at 440 V for power circuit conforming to IEC 60947
- Country of Origin:
- France
- Eu Rohs Directive:
- Compliant
- Product Or Component Type:
- contactor
- Warranty: