Schneider Electric LC1D50AKUE IEC contactor, TeSys Deca Green, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 100/250VAC/VDC coil
Schneider Electric
$115.00
TeSys D Green contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Equipped with an electronic coil, wide band voltage 100-250V, AC/DC compatible, low consumption. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
- Rohs Exemption Information:
- Yes
- Utilisation Category:
- AC-1 || AC-3 || AC-3e
- Mechanical Robustness:
- vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor open 10 Gn for 11 ms) || shocks contactor closed 15 Gn for 11 ms)
- Depth:
- 120 mm
- Range:
- TeSys || TeSys Deca
- Poles Description:
- 3P
- Environmental Disclosure:
- ENVPEP1607010EN
- Halogen Content Performance:
- Halogen free plastic parts & cables product
- Standards:
- EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || IEC 60335-1
- Protective Cover:
- with
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Ip Degree Of Protection:
- IP20 front face IEC 60529
- Operating Altitude:
- 0...9842.52 ft (0...3000 m)
- Motor Power Kw:
- 15 kW at 220...230 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50 Hz (AC-3) || 25 kW at 415 V AC 50 Hz (AC-3) || 30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 H
- [Ith] Conventional Free Air Thermal Current:
- 80 A (at 60°C) for power circuit || 10 A (at 60°C) for Signaling circuit
- [Icw] Rated Short-Time Withstand Current:
- 100 A - 1 s for Signaling circuit || 120 A - 500 ms for Signaling circuit || 140 A - 100 ms for Signaling circuit || 84 A 40°C - 10 min for power circuit || 208 A 40°C - 1 min for power circuit || 400 A 40°C - 10 s for power circuit || 810 A 40°C - 1
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947
- Width:
- 55 mm
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Mercury Free:
- Yes
- Product Certifications:
- CCC || CSA || EAC || UL || KC || DNV-GL || LROS (Lloyds register of shipping) || UKCA
- Contactor Application:
- motor control || resistive load
- Device Short Name:
- LC1D
- Auxiliary Contacts Type:
- mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Average Impedance:
- 1.5 mOhm - Ith 80 A 50 Hz for power circuit
- Eu Rohs Directive:
- Compliant with Exemptions
- Associated Fuse Rating:
- 10 A gG for Signaling circuit conforming to IEC 60947-5-1 || 100 A gG at <= 690 V coordination type 1 for power circuit || 100 A gG at <= 690 V coordination type 2 for power circuit
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-1
- Compatibility Code:
- LC1D
- Control Circuit Type:
- AC/DC 50/60 Hz AC/DC electronic
- Warranty:
- 18 months
- Overvoltage Category:
- III
- Climatic Withstand:
- IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
- Fire Resistance:
- 850°C IEC 60695-2-1
- Hold-In Power Consumption In W:
- 1.2-1.2 W 20°C
- Pole Contact Composition:
- 3 NO
- Connections - Terminals:
- control circuit: screw clamp terminals 1 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 2 1-4 mm² - cable stiffness: flexible without cable end || control circuit: screw clamp terminals 1 1-4 mm² -
- Non-Overlap Time:
- 1.5 ms on de-energisation between NC and NO contact || 1.5 ms on energisation between NC and NO contact
- Weight:
- 0.997 kg
- Signaling Circuit Frequency:
- 25...400 Hz
- [Ie] Rated Operational Current:
- 80 A (at <60°C) at <= 440 V AC-1 for power circuit || 50 A (at <60°C) at <= 440 V AC-3 for power circuit || 50 A (at <60°C) at <= 440 V AC-3e for power circuit
- Flame Retardance:
- V1 conforming to UL 94
- Product Or Component Type:
- contactor
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Coil Technology:
- built-in bidirectional peak limiting
- Irms Rated Making Capacity:
- 900 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for Signaling circuit conforming to IEC 60947-5-1 || 250 A DC for Signaling circuit conforming to IEC 60947-5-1
- Mounting Support:
- rail || plate