Schneider Electric

Schneider Electric LC1D50B7 IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VAC 50/60Hz coil, open

(No reviews yet) Write a Review
SKU:
LC1D50B7
MPN:
LC1D50B7
Condition:
New
Rated Breaking Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947
[Ui] Rated Insulation Voltage:
power circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1 || control circuit 600 V CSA || control circuit 600 V UL
Associated Fuse Rating:
100 A gG at <= 690 V coordination type 2 for power circuit || 10 A gG for control circuit conforming to IEC 60947-5-1 || 125 A gG at <= 690 V coordination type 1 for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mechanical Durability:
6000000 cycles
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947
Product Or Component Type:
contactor
Auxiliary Contacts Type:
mechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Protective Cover:
with
Utilisation Category:
AC-1 || AC-2 || AC-3e
Poles Description:
3P
Power Dissipation Per Pole:
3.7 W AC-3e || 9.6 W AC-1 || 6.3 W AC-3
Mounting Support:
rail
Control Circuit Type:
AC 50/60 Hz
Country of Origin:
Czechia
Mercury Free:
Yes
Control Circuit Voltage Limits:
0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz
Irms Rated Making Capacity:
1000 A at 440 V for power circuit conforming to IEC 60947 || 140 A AC for control circuit conforming to IEC 60947-5-1
Eu Rohs Directive:
Compliant
Environmental Disclosure:
ENVPEP110205EN
Range:
TeSys
[Uc] Control Circuit Voltage:
120 V AC 50/60 Hz
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC 25...400 Hz
Maximum Operating Rate:
3600 cyc/h 60°C
Reach Free Of Svhc:
Yes
Ip Degree Of Protection:
IP2X IEC 60529 || IP2X VDE 0106
Operating Time:
4...19 ms opening || 12...26 ms closing
Pvc Free:
Yes
Contactor Application:
resistive load
Net Weight:
1.4 kg
Product Certifications:
GOST || GL || DNV || LROS (Lloyds register of shipping) || CCC || RINA || BV || UKCA || UL
Climatic Withstand:
IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Height:
122 mm
[Ie] Rated Operational Current:
50 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 80 A (at <60°C) at <= 440 V AC AC-1 for power circuit || 65 A (at <60°C) at <= 440 V AC AC-3 for power circuit
Coil Technology:
without built-in bidirectional peak limiting diode suppressor
Quantity Per Set:
set of 10
Standards:
EN 60947-5-1 || UL 508 || IEC 60947-4-1 || IEC 60947-5-1
Inrush Power In Va:
140-140 VA cos phi 0.75 (at 20°C) || 160-160 VA cos phi 0.75 (at 20°C)
Heat Dissipation:
4-5 W at 50/60 Hz for control circuit
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Flame Retardance:
V1 conforming to UL 94
Maximum Horse Power Rating:
15 hp at 200/208 V AC 60 Hz for 3 phase motors || 15 hp at 230/240 V AC 60 Hz for 3 phase motors || 40 hp at 460/480 V AC 60 Hz for 3 phase motors || 40 hp at 575/600 V AC 60 Hz for 3 phase motors || 5 hp at 115 V AC 60 Hz for 1 phase motors || 10 hp
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Power Kw:
30 kW at 440 V AC 50 Hz (AC-3) || 30 kW at 500 V AC 50 Hz (AC-3) || 33 kW at 660...690 V AC 50 Hz (AC-3) || 15 kW at 220...230 V AC 50 Hz (AC-3) || 11 kW at 400 V AC 50 Hz (AC-4) || 30 kW at 1000 V AC 50 Hz (AC-3) || 22 kW at 380...400 V AC 50 Hz (AC
Minimum Switching Current:
5 mA for control circuit
Depth:
120 mm
$388.80

Description

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.